Siemens HMXD63B700 molded case circuit breaker is rated 700A with 3 poles and voltage ratings of 240VAC, 480VAC, 600VAC and 500VDC. UL 489 interrupting ratings are 65kA at 480VAC and 50kA at 600VAC. This SENTRON HMXD6 series breaker has an MD-Frame, thermal magnetic trip, LI trip function, fixed thermal and adjustable magnetic settings, and standard protection. Mounting is unit mount, with no lugs. It is 3-phase, measures 6 in deep and 9 in wide, and has an operating temperature of 40 °C. Standards are RoHS and REACh.
Siemens Switchboards, Panelboards, Motor Control Centers
Max Wire
500 kcmil
Protection and operation
Trip Technology
Thermal Magnetic
Trip Function Code
LI
Trip Function
Long-Time, Instantaneous
Trip Adjustability
Fixed Thermal, Adjustable Magnetic
Standards and features
Temp Rating
40C
Product FAQs
7 answers
What current rating should I use when selecting the Siemens HMXD63B700?
The Siemens HMXD63B700 is rated 700A. Use that rating when coordinating breaker selection with the circuit load and conductor protection requirements.
Can this breaker be selected for AC or DC circuits?
Its rated voltages are 240VAC, 480VAC, 600VAC and 500VDC. Select the voltage rating that matches the circuit, keeping AC and DC ratings separate.
How do I check its interrupting rating against available fault current?
The UL 489 interrupting ratings are 65kA at 480VAC and 50kA at 600VAC. At the applicable voltage, the available fault current at the installation point must not exceed that interrupting rating.
What does the three-pole configuration mean for a three-phase circuit?
This is a three-pole breaker for three-phase use, giving each phase conductor a breaker pole. Use that configuration when planning protection for the three phase conductors.
How does the thermal-magnetic LI trip work, and what can I adjust?
The LI thermal-magnetic trip provides long-time overload protection and instantaneous short-circuit protection. The thermal setting is fixed, while the magnetic setting is adjustable so its pickup can be selected as part of protection coordination.
Are cable lugs included for conductor termination?
No Lugs means cable lugs are not included with the breaker. Account for conductor termination hardware when planning the installation.
What mounting format and dimensions should I account for?
This MD-Frame breaker uses unit mounting and measures 9.00 in wide by 6.00 in deep. Use the mounting format and these dimensions when planning the mounting location and installation layout.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.