Built for overcurrent protection, the Siemens MP22020 miniature circuit breaker has a triplex arrangement. It is rated 20/20A with 4 poles, 120/240VAC and an interrupting rating of 10kAIC at 120/240VAC. The MH-T series uses plug-on mounting with fixed thermal and magnetic trips for long-time and instantaneous protection. Load side lug terminals accept 14-8 AWG wire. Approvals are UL and CSA, with RoHS, REACh, SWD and HACR standards.
How should I use the Siemens MP22020's 20/20A rating when selecting circuit protection?
The 20/20A rating is the current rating used for overcurrent protection selection. Match it to the circuit's load and conductor protection requirements, rather than selecting by voltage alone.
What electrical system should I evaluate the MP22020 for?
The MP22020 is rated for 120/240VAC, single-phase service. Use these ratings to check the circuit's voltage and phase when selecting protection.
How do I check whether its interrupting rating is adequate?
The interrupting rating is 10kAIC at 120/240VAC. Available fault current at the installation point must not exceed that rating; the interrupting rating concerns fault-clearing capability, not normal load current.
How does the thermal-magnetic trip protect the circuit, and can I adjust it?
Thermal-magnetic protection combines a long-time response to sustained overcurrent with an instantaneous response to high fault current. Both the thermal and magnetic trip settings are fixed, so select the breaker rating rather than planning to adjust its trip settings.
How are the breaker mounting and load-wire connections made?
The breaker uses plug-on mounting and a load-side lug for the outgoing conductor. These are separate installation interfaces: the plug-on connection mounts the breaker, while the lug terminates the load wire.
What conductor sizes can I terminate at the load lug?
The wire range is 14-8 AWG. Select a conductor within that terminal range that also meets the circuit's ampacity requirements; terminal acceptance alone does not determine conductor sizing.
Does the MP22020 require a neutral connection to the breaker?
A neutral connection to the breaker is not applicable. Keep any circuit neutral routing separate from the breaker's load-side lug connections.
What does the HACR marking mean when selecting circuit protection?
HACR refers to heating, air-conditioning and refrigeration applications. The marking is relevant when selecting overcurrent protection for those types of loads.
What does the SWD marking mean for using the breaker as a switch?
SWD means switch duty and relates to switching fluorescent lighting loads. Use this marking when selecting a breaker that will also serve as the switching device for that type of load.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 5.0 out of 5 based on 4 reviews.
Thank you so much for sending me a 100 amp breaker that was in the condition that you said it would be in.With out your breaker I would still be in the dark Thank you David