Engineered for demanding residential and commercial applications, the Siemens QS2175HH provides 175 amps of reliable main service protection. This two-pole plug-on unit features an extra-high 65kAIC interrupting capacity at 120/240VAC. It mounts into Siemens Power Mod meter stacks, Uni-PAK metering, and legacy Murray load centers. Featuring a side-wired design with right-hand bend wiring, it eliminates the need for filler plates and serves as an exact replacement for the MDH2175.
Siemens Power Mod Meter Stacks, Uni-PAK Metering, Legacy Murray Load Centers
Wire Gauge
3 AWG - 300 kcmil (Cu/Al)
Max Wire
300 kcmil
Min Wire
3 AWG
Protection and operation
Trip Technology
Thermal Magnetic
Trip Function Code
LI
Trip Function
Long-Time, Instantaneous
Trip Adjustability
Fixed
Standards and features
Available Options
Padlock Attachment
Standards
UL 489, CSA C22.2 No. 5
Approval
CSA, UL
Temp Rating
40C
Construction Features
HACR Rated, Extra High Interrupting Capacity, Side-wired design, Right-hand bend wiring, No filler plates required, Common Trip
Product FAQs
6 answers
What equipment is the Siemens QS2175HH breaker compatible with?
This main breaker is designed for use in Siemens Power Mod meter stacks, Uni-PAK multi-family metering enclosures, and legacy Murray load centers.
Can the QS2175HH be used to replace a Murray MDH2175?
Yes, the Siemens QS2175HH serves as an exact replacement for the legacy Murray MDH2175 main breaker.
What is the difference between the QS2175, QS2175H, and QS2175HH breakers?
The difference is the interrupting rating. The QS2175 is rated at 10kAIC, the QS2175H is rated at 22kAIC, and the QS2175HH offers an extra-high 65kAIC rating at 240V.
Does the QS2175HH require filler plates when installed in a meter stack?
No, this breaker features a compact side-wired design with right-hand bend wiring that eliminates the need for filler plates in compatible enclosures.
Is the Siemens QS2175HH breaker HACR rated?
Yes, this breaker is HACR rated, making it suitable for protecting heating, air conditioning, and refrigeration equipment circuits.
Does the QS2175HH feature a common trip mechanism?
Yes, it features an internal common trip mechanism. In the event of an overload or short circuit on either pole, both poles will trip simultaneously to safely disconnect power.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.