Built for residential and commercial distribution, the Siemens QSH2100 is a 2-pole, 100A molded case circuit breaker. It provides reliable thermal-magnetic protection for main breaker applications. This plug-on MCCB mounts into Siemens Power Mod meter stacks, Uni-PAK metering, and WMM series load centers. The side-wired configuration ensures a straightforward installation process.
Siemens Power Mod Meter Stacks, Siemens Uni-PAK, Siemens WMM Series, Siemens Load Centers
Wire Gauge
3 AWG - 300 kcmil (Cu/Al)
Max Wire
300 kcmil
Min Wire
3 AWG
Protection and operation
Trip Technology
Thermal Magnetic
Trip Function Code
LI
Trip Function
Long-Time, Instantaneous
Trip Adjustability
Fixed
Standards and features
Available Options
Padlock Attachment
Standards
CSA C22.2 No. 5, UL 489
Approval
CSA, UL
Temp Rating
40°C
Construction Features
42kA High Interrupting Rating, Side-Wired Design, HACR Rated
Product FAQs
5 answers
What equipment is the Siemens QSH2100 circuit breaker designed for?
The QSH2100 is a main breaker designed for use in Siemens Power Mod meter stacks, Uni-PAK metering, WMM series residential meter stacks, and compatible Siemens load centers.
Can the QSH2100 be installed in systems that only require a 10kAIC or 22kAIC rating?
Yes. With its 42kAIC interrupting rating, the QSH2100 exceeds the requirements for 10kAIC and 22kAIC applications and can be safely installed where lower fault current ratings are specified.
What is the difference between the Siemens QS2100, QS2100H, QSH2100, QS2100HH, and HQS2100H?
These breakers share the same physical QS frame and 100A rating but differ in their interrupting capacity. The QS2100 is rated at 10kAIC, the QS2100H at 22kAIC, the QSH2100 at 42kAIC, the QS2100HH at 65kAIC, and the HQS2100H at 100kAIC.
Can the QSH2100 replace older Murray main breakers?
Yes, the Siemens QSH2100 is a direct, modern replacement for discontinued Murray MD-H series breakers, such as the MDH2100, with offset lugs. This makes it compatible with many legacy Murray and Crouse-Hinds metering panels.
Can the QSH2100 be used as a tenant main breaker in multi-family metering?
Yes, the QSH2100 is specifically designed to serve as a dedicated tenant main breaker in multi-family residential and commercial metering applications.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.