Engineered for industrial applications, the Siemens SHMD69800A is a 3-pole, 800A molded case circuit breaker from the Sentron MD Frame family. This unit-mount breaker installs into Siemens Sentron panelboards. For legacy upgrades, it is replaced by the 3VA6580-6HL32-0AA0 (requires a retrofit kit). Rated at 65 kAIC at 480V, it features a Sensitrip III electronic trip unit with adjustable long-time and instantaneous (LI) functions. It is HACR rated.
Siemens Sentron Panelboards, Switchboards, Motor Control Centers
Wire Gauge
(3) 1/0 AWG - 500 kcmil (Cu/Al)
Max Wire
500 kcmil
Min Wire
1/0 AWG
Protection and operation
Trip Technology
Electronic Trip
Trip Function Code
LI
Trip Function
Long-Time, Instantaneous
Trip Adjustability
Adjustable
Standards and features
Available Options
Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Lug Kits
Accessories
Line and Load Lugs (TA3K500)
Standards
CSA C22.2 No. 5, IEC 60947-2, UL 489
Approval
CSA, IEC, UL
Temp Rating
40C
Construction Features
HACR Rated, Reverse Feed, High Interrupting Capacity, True RMS Sensing
Product FAQs
8 answers
What panelboards and enclosures are compatible with the SHMD69800A?
This MD-frame breaker is designed for use in Siemens Sentron panelboards, switchboards, and motor control centers.
Is there a direct replacement for the legacy SHMD69800A breaker?
Yes, for legacy upgrades, it is replaced by the Siemens 3VA6580-6HL32-0AA0. Note that installing the newer 3VA series breaker will require a retrofit kit.
Can the SHMD69800A be reverse fed?
Yes, this breaker is acceptable for reverse connection applications.
What wire sizes are accepted by the lugs on this breaker?
The standard lugs accept three 1/0 AWG to 500 kcmil copper or aluminum conductors per phase.
What lug kit is used with the SHMD69800A?
The standard line and load lug kit for this breaker is the TA3K500.
What trip unit is installed in the SHMD69800A?
It features a Sensitrip III electronic trip unit with True RMS sensing and adjustable long-time and instantaneous (LI) functions.
Is this breaker HACR rated?
Yes, the SHMD69800A is HACR rated for use with heating, air conditioning, and refrigeration equipment.
What safety standards does the SHMD69800A meet?
This breaker is UL 489 listed and meets CSA C22.2 No. 5 and IEC 60947-2 standards.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.