Skip to main content

Siemens SHND6B100LSIH Molded Case Circuit Breaker

  • 1000A
  • 3 Pole
  • Unit Mount
Siemens SHND6B100LSIH
Molded Case Circuit Breaker
Brand Siemens
SKU SHND6B100LSIH
Select Item Condition
Earn 7763 SuperPoints
  • 1000A
  • 3 Pole
  • Unit Mount

Quantity

Bulk Pricing
Send your parts list for a volume quote.

Siemens SHND6B100LSIH - 1000A 3 Pole Molded Case Circuit Breaker

New

$7,763.88 Check Stock

Quantity

Description

Engineered for heavy-duty applications, the Siemens SHND6B100LSIH is a 1000A electronic trip MCCB. This unit-mount breaker installs into Sentron P4 and P5 panelboards, SB-series switchboards, and motor control centers. For modern upgrades, it is replaced by the 3VA6610-6HN32-0AA0 frame. Rated for 65kAIC at 480VAC, it features adjustable Long-Time, Short-Time, and Instantaneous (LSI) settings and a 100% continuous current rating for precise coordination in demanding electrical systems.

Specifications

Key specifications
Brand Siemens
Part Number SHND6B100LSIH
Series SHND6
Amperage 1000A
Poles 3
Mounting Style Unit Mount
Voltage 240VAC, 480VAC, 600VAC
Phase 3
AIC Rating 100kA @ 240VAC, 65kA @ 480VAC, 50kA @ 600VAC
Fit and installation
Frame Type SND
Terminal Type Lugs
For Use With Siemens Sentron Panelboards (Type P4, P5), Switchboards (SB1, SB2, SB3), Motor Control Centers
Protection and operation
Trip Technology Electronic Trip
Trip Function Code LSI
Trip Function Long-Time, Short-Time, Instantaneous
Trip Adjustability Adjustable
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release, Lug Kits
Accessories Lugs Not Included
Standards CSA C22.2 No. 5, IEC 60947-2, NEMA AB-1, UL 489
Approval CSA, UL
Temp Rating 40C
Construction Features 100% Rated, Solid State Trip Unit, High Interrupting Capacity, HACR Rated, True RMS Sensing

Product FAQs

7 answers
Which panelboards and switchboards are compatible with the SHND6B100LSIH?

This ND-frame circuit breaker is designed for installation in Siemens Sentron P4 and P5 panelboards, SB1, SB2, and SB3 switchboards, as well as compatible motor control centers.

What does the LSI designation mean on this electronic trip unit?

LSI indicates the Sensitrip IV solid-state trip unit features adjustable Long-Time, Short-Time, and Instantaneous protection settings, allowing for precise coordination with other protective devices in the system.

What is the modern replacement for the SHND6B100LSIH?

For modern panel upgrades or replacements, Siemens recommends the 3VA6 series, specifically the 3VA6610-6HN32-0AA0 frame, to replace this legacy Sentron ND-frame breaker.

What lug kits are compatible with this ND-frame circuit breaker?

For wire termination, you can use Siemens lug kits such as the 3TA2N8750, which accepts 500 to 750 kcmil copper or aluminum conductors, or the TC2K500 copper-body lug kit for 1 AWG to 500 kcmil wire.

How is this circuit breaker mounted in an electrical enclosure?

This is a unit-mount circuit breaker. It bolts directly to the mounting pan or chassis of individual enclosures, panelboards, and switchboards, rather than plugging into a busbar.

Can the SHND6B100LSIH be reverse fed?

Yes, according to Siemens specifications, Sentron ND-frame breakers with non-removable trip units are suitable for reverse feed applications under UL 489 guidelines.

What safety precautions are required when installing the SHND6B100LSIH?

Always de-energize and lock out all incoming power supplying the equipment before working on or installing the breaker. Installation and maintenance must only be performed by qualified electrical personnel in accordance with local codes.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.