Built to protect circuits against overloads and short circuits, the Milbank UQFB-100 is a 2-pole molded case circuit breaker rated 100A and 240VAC, with an interrupting rating of 10kAIC at 240V. It belongs to the UQFB series and uses an F frame with bolt-on mounting. Fixed thermal and fixed magnetic tripping provide long-time and instantaneous protection. The breaker has load side lug terminals and UL approval.
How should I use the Milbank UQFB-100's 100A rating when selecting a breaker?
The 100A rating is the breaker's rated current, not its short-circuit interrupting capacity. Select it by coordinating the circuit load and conductor ampacity with the applicable installation requirements.
What electrical configuration is the UQFB-100 rated for?
The UQFB-100 is a 2-pole breaker rated for 240VAC, single-phase service. Use these ratings to match the circuit voltage, phase and number of poles required.
How do I check whether the interrupting rating is adequate?
The interrupting rating is 10kAIC at 240V. Available fault current at the installation point must not exceed that rating when selecting the breaker for that voltage.
How does the thermal-magnetic trip operate, and can I adjust it?
Thermal-magnetic protection provides a long-time response to sustained overloads and an instantaneous response to high fault current. Both the thermal and magnetic trip settings are fixed, so select the breaker for its built-in trip characteristics rather than field adjustment.
How is the breaker mounted, and where do the outgoing conductors connect?
The breaker uses bolt-on mounting and a load-side lug connection. Plan for a bolted mounting installation and terminate the outgoing circuit conductors at the load-side lug.
What dimensions should I allow for installation planning?
The breaker measures 7.44 in high, 3.28 in wide and 3 in deep. Use these dimensions to plan the breaker footprint, with additional space for conductor routing and installation access.
Is the UQFB-100 UL approved?
The UQFB-100 has UL approval. This supports selection where UL safety evaluation is a procurement or project requirement.
What copper and aluminum conductor sizes can I terminate?
The conductor ranges are 3-1 AWG (Cu) and 1-1/0 AWG (Al). Choose a size within the range for your conductor material that also meets the circuit's ampacity requirements.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 5.0 out of 5 based on 1 review.