Designed for remote shutdown capabilities, this 100A thermal-magnetic breaker incorporates a 120-240VAC shunt trip mechanism. It supports industrial operations where automated or emergency tripping is necessary. Fastening via standard unit mounting hardware, the component integrates into Square D switchboards. Maintenance teams replacing this unit can utilize the PowerPact HGL36100SA along with a retrofit kit. Rated for 65kAIC at 240V, the F-frame device mitigates severe fault currents.
What does the "-1021" suffix indicate on the FHL36100-1021?
The "-1021" suffix designates a factory-installed 120/240VAC shunt trip accessory. This allows the breaker to be tripped remotely via an external control signal, which is commonly used for emergency shutdown or fire alarm integration.
What equipment is compatible with this unit-mount breaker?
As a feed-thru, unit-mount F-frame breaker, it is designed for installation in compatible Square D enclosures, switchboards, and motor control centers. It is not compatible with I-Line panelboards, which require plug-on mounting.
How is the FHL36100-1021 physically installed?
This is a unit-mount circuit breaker, meaning it bolts directly to a backpan or mounting plate within an enclosure or switchboard. It uses feed-thru lug connections for both the line and load sides.
What are the acceptable wire sizes for the FHL36100-1021 lugs?
The standard lugs on this breaker accept 14 AWG to 1/0 AWG copper (Cu) conductors, or 12 AWG to 1/0 AWG aluminum (Al) conductors. Ensure proper torque specifications are followed during installation.
Can the trip settings on the FHL36100-1021 be adjusted in the field?
No, this breaker features a fixed thermal-magnetic trip unit. Both the long-time (overload) and instantaneous (short circuit) trip functions are factory-set and non-adjustable.
Is this breaker suitable for direct current (DC) systems?
Yes, in addition to its AC ratings, the FHL36100-1021 is rated for use in DC applications up to 250VDC.
Does this breaker include ground fault equipment protection (GFEP)?
No, the FHL36100-1021 provides standard thermal-magnetic protection against overloads and short circuits only. It does not feature ground fault or arc fault sensing capabilities.
Can I use the FHL36100-1021 to replace an older F-frame breaker?
Yes, this breaker can replace legacy Square D F-frame unit-mount breakers with matching specifications (100A, 3-pole, 600VAC). However, verify that your application requires the 120/240VAC shunt trip included with this specific "-1021" model.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 4.7 out of 5 based on 3 reviews.