Built for heavy-duty industrial environments, the Square D FI26100AB is a 100A, two-pole current-limiting MCCB. It restricts let-through energy during short circuits to protect downstream equipment. This legacy F-frame breaker utilizes an A-B phase connection and installs into Square D I-Line panelboards. It is replaced by the HLA261001, which has a reduced 100kAIC rating at 480V. Delivering a 200kAIC capacity at 480V, it uses thermal-magnetic trip technology for dependable fault response.
Current Limiting, HACR Rated, Visual Trip Indicator
Special Features
Current Limiting
Product FAQs
7 answers
What does the AB suffix in the FI26100AB catalog number indicate?
The AB suffix specifies the phase connection for the I-Line plug-in mounting. It indicates that this 2-pole breaker connects to the A and B phases on the panelboard busbar.
What panelboards are compatible with the FI26100AB circuit breaker?
This breaker is designed exclusively for use in Square D I-Line panelboards and switchboards. It mounts directly to the internal I-Line bus assembly.
How does the I-Line plug-in connection work under fault conditions?
The I-Line mounting system uses a blow-on jaw design. During a high-level short circuit, the magnetic forces generated by the fault current force the jaws tighter against the busbar, ensuring a secure electrical connection.
Is the Square D FI frame still in active production?
The F-frame is a legacy product and is no longer manufactured by Schneider Electric. For new installations or direct replacements, the PowerPact B or H-frame series is the modern equivalent, though specific I-Line adapter requirements may apply.
What makes the FI26100AB a current-limiting circuit breaker?
Current-limiting breakers like the FI series are designed to clear severe short circuits extremely fast, typically within a half-cycle. This rapid response limits the peak let-through current and thermal energy delivered to downstream equipment during a fault.
What is the recommended tightening torque for the load-side lugs?
For the standard AL100FA lugs used on 100A F-frame breakers, the recommended terminal tightening torque is 50 lb-in (5.6 N.m) for 14 to 1/0 AWG conductors.
Can the trip settings on the FI26100AB be adjusted in the field?
No, the thermal-magnetic trip unit is fixed. The long-time and instantaneous trip thresholds are factory set and cannot be modified in the field.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.