Built for demanding industrial applications, this 15-amp, two-pole molded case circuit breaker provides essential thermal-magnetic protection. The PowerPacT B-Frame construction ensures durability while minimizing panel space. It mounts into standard I-Line panelboards and switchboards, and replaces older FA24015BC breakers to ensure a smooth transition for maintenance. Operating with a BC phase connection, it delivers an 18 kAIC rating at 480VAC and features dual-break rotating contacts.

Specifications

Key specifications
Brand Schneider Electric
Series BDA
Amperage 15A
Poles 2
Mounting Style I-Line
Voltage 208Y/120VAC, 240VAC, 480Y/277VAC, 480VAC, 600Y/347VAC, 250VDC
Phase 1
AIC Rating 25kA @ 208Y/120VAC, 25kA @ 240VAC, 18kA @ 480Y/277VAC, 18kA @ 480VAC, 10kA @ 600Y/347VAC, 10kA @ 250VDC
Fit and installation
Frame Type BDA
Terminal Type Lugs
For Use With I-Line Panelboards, Switchboards
Wire Gauge 14 AWG - 2/0 AWG
Max Wire 2/0 AWG
Min Wire 14 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Fixed Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment
Accessories I-Line Phase Connection: BC (Suffix Y4)
Standards CSA C22.2 No 5, EN/IEC 60947-2, EN/IEC 60947-5-1, GB 14048.2, NEMA AB 1, NMX J-266, UL 489
Approval CCC, CE, CSA, EAC, IEC, NOM, UKCA, UL
Temp Rating -25C to 70C
Construction Features HACR Rated, Dual-Break Rotating Contacts, Push-to-Trip

Product FAQs

6 answers
What type of panelboards are compatible with the BDA24015Y4?

This breaker is designed exclusively for Square D and Schneider Electric I-Line panelboards and switchboards. It utilizes an I-Line style plug-in connection that mounts directly onto the panel's internal bus assembly.

What does the "Y4" suffix indicate on the BDA24015Y4 catalog number?

The "Y4" suffix designates a BC phase connection. When installed in an I-Line panelboard, this 2-pole breaker will draw power specifically from the B and C phases of the busbar.

What does the "D" in the BDA frame designation mean?

In the PowerPacT B-frame series, the second letter indicates the interrupting capacity tier. The "D" signifies an 18 kA interrupting rating at 480Y/277VAC and 25 kA at 240VAC.

Can the trip settings on the BDA24015Y4 be adjusted in the field?

No, this breaker features a fixed thermal and fixed magnetic trip unit. The Long-Time and Instantaneous (LI) protection parameters are factory-set and cannot be modified.

Is the BDA24015Y4 suitable for direct current (DC) systems?

Yes, this thermal-magnetic breaker is dual-rated for both AC and DC applications. It provides a 10 kA interrupting capacity for systems operating up to 250VDC.

What wire sizes are accepted by the standard lugs on the BDA24015Y4?

The factory-installed lugs on this 15A breaker accept either aluminum or copper wire ranging from 14 AWG to 2/0 AWG.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.