Built for residential safety, the Square D HOM115GFI delivers 15A of Class A ground fault protection. This single-pole breaker operates at 120VAC and features a pigtail neutral wire. It mounts into Square D Homeline load centers using a simple plug-on connection, accepting 14-8 AWG wiring via screw clamp terminals. Rated for a 10kAIC interrupting capacity, it trips when a fault current to ground exceeds 6mA. The breaker is HACR rated and UL listed for reliable performance.
HACR Rated, UL 489, UL 943, CSA C22.2 No. 5, CSA C22.2 No. 144
Approval
CSA, UL
Temp Rating
40C
Construction Features
HACR Rated, Mercury Free, RoHS Compliant
Product FAQs
8 answers
Can I install the HOM115GFI in a Square D QO load center?
No. This breaker is exclusively designed for Square D Homeline load centers. QO panels require QO series breakers.
Does this breaker require a Plug-On Neutral panel?
No. The HOM115GFI features a pigtail neutral wire that connects directly to the panel neutral bus bar, making it compatible with both standard and Plug-On Neutral Homeline load centers.
What is the difference between the HOM115GFI and the HOM115GFIC?
The breakers are identical. The "C" at the end of HOM115GFIC simply indicates that the breaker comes in clamshell retail packaging.
What is the Plug-On Neutral equivalent of this breaker?
If you prefer a breaker that connects directly to the neutral bar without a pigtail wire, the Plug-On Neutral equivalent is catalog number HOM115PGFI.
What class of ground-fault protection does the HOM115GFI provide?
It provides Class A ground-fault protection, meaning it is designed to trip when it detects a ground fault of 5mA to 6mA. This is the standard required for personnel protection in wet locations.
Does this breaker provide arc-fault protection?
No. The HOM115GFI is strictly a Ground-Fault Circuit Interrupter (GFCI). If you need dual-function protection for both AFCI and GFCI, you will need a different breaker, such as the HOM115DF.
What is the recommended tightening torque for the load terminals?
The screw clamp terminals should be torqued to 35.4 lb-in for 14 AWG to 8 AWG wire.
Can I land two wires on the load terminal of this breaker?
Yes, the clamp terminal is rated to accept up to two 14 AWG to 10 AWG copper wires. If using aluminum wire, it only accepts a single 14 AWG to 8 AWG conductor.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.