Providing dedicated 240-volt personnel protection, this 15-amp two-pole breaker is essential for specialized residential loads like pool pumps or outdoor receptacles. The unit installs into traditional Square D Homeline panelboards and utilizes a standard pigtail wire to establish the neutral connection. Featuring a 10kAIC rating and thermal-magnetic trip mechanisms, it guarantees reliable defense against both dangerous ground faults and damaging overcurrent events.
Can the HOM215GFI be installed in a Square D QO load center?
No. Homeline breakers are strictly designed for Square D Homeline load centers. They use a 1-inch format that is not physically interchangeable with the 3/4-inch QO series panels.
Does this breaker require a plug-on neutral panel design?
No. This specific unit features a pigtail neutral connection. It works in both legacy standard panels and modern plug-on neutral Homeline load centers, but you must manually route and terminate the attached white pigtail wire to the neutral bus bar.
How much physical panel space does this unit occupy?
As a two-pole Homeline breaker, it requires two adjacent standard 1-inch spaces on the load center bus.
Is this breaker suitable for multi-wire branch circuits?
Yes. A two-pole GFCI is required when providing ground fault protection for multi-wire branch circuits where two 120V circuits share a common neutral conductor, or for dedicated 240V equipment requiring personnel protection.
What type of ground fault protection does this model provide?
It provides Class A ground fault protection. The breaker is calibrated to trip and open the circuit when it detects a ground fault leakage current between 4 and 6 milliamperes, which is the standard required to protect personnel from electrical shock.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 2.5 out of 5 based on 2 reviews.
My pool motor stopped running, and I found a breaker fault causing the problem. I could not find one locally, and SuperBreakers had a reasonable price with free delivery. I called and asked where they were located, as I wanted it ASAP. The New York gentleman I spoke with checked his inventory and said it would go out that afternoon. When it arrived, it was a snap to get my motor running again.