Built for commercial power distribution, this 60A three-pole breaker incorporates a 120VAC shunt trip for automated or remote circuit interruption. It fastens securely into Square D NF panelboards, ensuring a reliable bolt-on connection for 480Y/277V systems. The E-frame design boasts a 65kA interrupting capacity at 240V, complete with HACR ratings and a Visi-Trip flag to quickly spot tripped circuits.
Which panelboards are compatible with the EGB34060SA?
This E-frame bolt-on circuit breaker is designed specifically for installation in Square D NF series panelboards.
What does the SA suffix mean in the EGB34060SA part number?
The SA suffix indicates that the breaker includes a factory-installed 120VAC shunt trip. This allows the breaker to be tripped remotely for emergency shutoff or control systems.
Does the shunt trip on the EGB34060SA require extra panel space?
Yes, the factory-installed shunt trip requires one additional pole space in the NF panelboard. This means the 3-pole breaker will occupy four spaces total.
Can I use this breaker on a 480V Delta electrical system?
No. Because it carries a slash voltage rating of 480Y/277VAC, it is only approved for use on solidly grounded Wye systems where the line-to-ground voltage does not exceed 277V. It cannot be used on ungrounded or corner-grounded 480V Delta systems.
What wire sizes are accepted by the lugs on the EGB34060SA?
The factory-installed lugs accept copper wire from 14 AWG to 2/0 AWG, or aluminum wire from 12 AWG to 2/0 AWG.
Are the trip settings on this 60A breaker adjustable?
No, the EGB34060SA features a thermal-magnetic trip unit with fixed long-time and fixed instantaneous trip settings that cannot be adjusted in the field.
Can I add a shunt trip to a standard EGB34060 in the field?
No, shunt trips for Square D E-frame breakers are not field-installable. You must purchase a breaker with a factory-installed shunt trip, such as the EGB34060SA, if remote tripping is required.
Is the EGB34060SA suitable for HVAC applications?
Yes, this breaker is HACR rated, meaning it is approved for use with heating, air conditioning, and refrigeration equipment.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 4.9 out of 5 based on 25 reviews.