Providing combination arc-fault mitigation for 240V applications or multi-wire branch circuits, this 20A two-pole breaker ensures comprehensive residential safety. It installs into traditional Square D Homeline load centers and utilizes a standard pigtail wire for the neutral connection. Rated for 10kA interrupting capacity, it complies with modern NEC standards for living areas requiring dual-pole AFCI coverage. The unit includes visual trip indicators for simplified maintenance.
Can I install the HOM220CAFI in a Square D QO load center?
No. This breaker is exclusively designed for Square D Homeline load centers. QO panels require QO series breakers, which utilize a different mounting mechanism.
What applications typically require a 2-pole combination arc fault breaker?
A 2-pole CAFI breaker is commonly used for 240V circuits or 120/240V multi-wire branch circuits (shared neutral applications) that require arc fault protection to meet NEC requirements.
Does this breaker feature a plug-on neutral or a pigtail neutral connection?
The HOM220CAFI features a standard pigtail neutral wire. It must be manually connected to the neutral bus bar in your load center, unlike Plug-on Neutral (PoN) breakers which connect directly to the neutral bus.
What does "Combination Arc Fault" (CAFI) mean on this breaker?
Combination Arc Fault breakers provide protection against both parallel arcs (line-to-neutral or line-to-ground) and series arcs (loose connections or damaged wires in series with the load).
Can I terminate two wires under the lugs of the HOM220CAFI?
Yes, the clamp terminals are rated to accept two copper wires ranging from 14 to 10 AWG. If you are terminating a single wire, the terminals accept 14 to 8 AWG copper or aluminum conductors.
How do I test the arc fault functionality after installation?
Once installed and energized, press the test button on the front of the breaker. The breaker should trip immediately, indicating the arc fault detection circuitry is functioning correctly.
What is the difference between the HOM220CAFI and HOM220CAFIC catalog numbers?
Both catalog numbers represent the exact same 20A 2-pole CAFI breaker. The "C" suffix simply indicates that the breaker is packaged in a retail clamshell rather than standard bulk packaging.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.