Providing advanced control for industrial applications, this 200A thermal-magnetic MCCB combines reliable protection with remote tripping capabilities. The unit mount configuration fits into Square D enclosures and switchboards. It acts as a replacement for legacy K-Frame installations, though the PowerPacT J-Frame is the current generation equivalent. A factory-installed shunt trip allows the breaker to be opened via an external voltage signal. It boasts a 65kA interrupting capacity at 240VAC.
Line and Load Lugs Included, Shunt Trip (Factory Installed)
Standards
CSA C22.2 No. 5, HACR, IEC 60947-2, NEMA AB 1, UL 489
Approval
CE, CSA, UL
Temp Rating
40C
Construction Features
High Interrupting Capacity, HACR Rated
Product FAQs
6 answers
What does the 1027 suffix mean on the KHL362001027?
The 1027 suffix indicates the inclusion of a factory-installed shunt trip accessory with a 24V DC coil. This allows the breaker to be opened remotely via a control signal, which is commonly used for emergency power-off or safety interlock systems.
How does the unit-mount design of the KHL362001027 differ from I-Line breakers?
As a unit-mount, feed-thru breaker, the KHL362001027 bolts directly to the backpan or mounting surface and requires wired connections on both the line and load sides. It is not compatible with I-Line plug-on panelboard bus systems.
What is the modern replacement for the legacy KHL362001027?
The Square D K-Frame is a legacy series. When upgrading or replacing this unit, Schneider Electric recommends the PowerPact J-Frame series, such as the JGL36200. Note that a separate 24V DC shunt trip accessory must be installed on the replacement to match the 1027 suffix functionality.
How does the adjustable magnetic trip work on this K-Frame breaker?
The thermal-magnetic trip unit features a fixed thermal element for overload protection and an adjustable magnetic element for instantaneous short-circuit protection. The magnetic dial allows electricians to fine-tune the trip threshold to coordinate with other downstream devices or handle motor inrush currents.
Can the KHL362001027 be used in DC electrical systems?
Yes, in addition to its AC ratings up to 600VAC, this breaker is rated for 250VDC systems. It provides an interrupting capacity of 10kAIC at 250VDC.
What type of conductors can be used with the standard lugs on this breaker?
The factory-installed lugs are rated for both aluminum and copper (Al/Cu) conductors. They accommodate wire sizes ranging from 4 AWG up to 350 kcmil.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.