Skip to main content
Expedited shipping available at checkout

Square D MAP26600 Molded Case Circuit Breaker

  • 600A
  • 2 Pole
  • Bolt-On
Square D MAP26600
Molded Case Circuit Breaker
Brand Square D
SKU MAP26600
Select Item Condition
Earn 2507 SuperPoints
  • 600A
  • 2 Pole
  • Bolt-On

Quantity

Bulk Pricing
Send your parts list for a volume quote.

Square D MAP26600 - 600A 2 Pole Molded Case Circuit Breaker

Re-Certified

$2,507.92 In Stock

Quantity

Description

Rated for 600A, this MAP-frame molded case circuit breaker is built to handle demanding commercial and industrial electrical systems. It delivers dependable thermal-magnetic protection with long-time and instantaneous trip capabilities. Designed for seamless integration, the breaker mounts into Square D I-Line panelboards and switchboards. It serves effectively as a vertical main with its secure bolt-on design.

Specifications

Key specifications
Brand Square D
Series MAP
Amperage 600A
Poles 2
Mounting Style Bolt-On
Voltage 240VAC, 480Y/277VAC, 480VAC, 600Y/347VAC, 600VAC, 250VDC
Phase 1
AIC Rating 42kA @ 240VAC, 30kA @ 480Y/277VAC, 30kA @ 480VAC, 22kA @ 600Y/347VAC, 22kA @ 600VAC, 14kA @ 250VDC
Fit and installation
Frame Type M
Terminal Type Lugs
For Use With Square D I-Line Panelboards (Vertical Main), Switchboards
Wire Gauge (3) 3/0 AWG - 500 kcmil (Al/Cu)
Max Wire 500 kcmil
Min Wire 3/0 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Adjustable Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch
Accessories Load Side Lugs Included
Standards CSA C22.2 No. 5, NEMA AB 1, UL 489
Approval CSA, UL
Temp Rating 40C
Construction Features Visual Trip Indicator, HACR Rated, Non-Interchangeable Trip

Product FAQs

8 answers
What equipment is the MAP26600 circuit breaker compatible with?

This breaker is designed for use in Square D switchboards and as a vertical main in I-Line panelboards. It is a unit-mount, bolt-on breaker and is not compatible with standard plug-on I-Line branch spaces or residential load centers.

How many conductors do the factory lugs on the MAP26600 accept?

The standard mechanical lugs are designed to accept three parallel conductors per phase. Each terminal accommodates aluminum or copper wire ranging from 3/0 AWG to 500 kcmil.

How does the adjustable magnetic trip function operate on this breaker?

The MAP26600 features a thermal-magnetic trip unit with a fixed thermal element for overload protection and an adjustable magnetic element. The adjustable magnetic setting allows electricians to tune the instantaneous short-circuit trip point to coordinate with specific load inrush currents, preventing nuisance tripping.

Is the Square D MAP frame still manufactured for new installations?

The MAP series is a legacy M-frame molded case circuit breaker. While it is still sourced for direct replacements in existing switchboards and motor control centers, modern Square D installations typically utilize the newer PowerPacT M-frame series.

Why is proper torque critical when terminating the 3/0 AWG to 500 kcmil conductors on this breaker?

Under-torqued lugs can lead to high resistance, localized heating, and thermal damage, while over-torquing can deform the conductors or strip the lug threads. Always use a calibrated torque wrench and follow the manufacturer specifications printed on the breaker faceplate to ensure a safe, code-compliant connection.

Can the MAP26600 be utilized in direct current (DC) systems?

Yes, in addition to its AC ratings, this breaker is rated for use in DC applications up to 250VDC, where it provides an interrupting rating of 14kA.

Can I use the MAP26600 as a branch breaker in an I-Line panelboard?

No. While it is compatible with I-Line panelboards, it is specifically configured as a vertical main breaker. It features a bolt-on connection rather than the plug-on jaw configuration required for I-Line branch mounting.

What does the M-frame designation indicate for the MAP26600?

The M-frame designation refers to the standardized physical dimensions of the breaker housing. All Square D legacy M-frame breakers share the same footprint and mounting hole patterns, allowing for straightforward physical replacement within compatible switchboards regardless of the specific amperage rating.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.