Built for heavy-duty applications, the Square D QJA221502 delivers reliable thermal-magnetic protection within the PowerPacT Q-Frame series. This breaker mounts into Square D I-Line panelboards and switchboards, providing a secure plug-on connection. It is fully compatible as a replacement for older Q22150 models. Delivering a 100 kAIC interrupting capacity at 240VAC, this two-pole unit includes an AC phase connection, current-limiting capabilities, and a visual trip indicator.
What panelboards are compatible with the QJA221502 circuit breaker?
This PowerPacT Q-frame breaker is designed exclusively for Square D I-Line panelboards and switchboards. It features an I-Line plug-in connection that mounts directly to the panel bus.
How does the I-Line connection on the QJA221502 secure to the panel bus?
The breaker utilizes blow-on type line-side connectors. During a short circuit, the increased magnetic flux causes the plug-on jaws to grasp the panelboard busbars even tighter, ensuring a secure electrical connection under fault conditions.
Can the QJA221502 be used to replace older Square D circuit breakers?
Yes, the PowerPacT Q-frame series is the direct replacement for legacy Square D Q2 series circuit breakers. The QJA221502 specifically replaces 150A, 2-pole Q2 breakers that utilize the I-Line plug-in mounting system.
What does the LI trip function code mean on the QJA221502?
The LI designation indicates that the thermal-magnetic trip unit provides Long-Time (L) protection for overloads and Instantaneous (I) protection for short circuits. Both the thermal and magnetic trip settings are fixed on this model.
Are the load-side lugs on the QJA221502 rated for aluminum wire?
Yes, the factory-installed mechanical lugs are dual-rated for both aluminum (Al) and copper (Cu) conductors. They accept a wide wire range from 4 AWG to 300 kcmil, providing flexibility for various field wiring requirements.
Is the QJA221502 suitable for use on 208Y/120V systems?
Yes, while it has a maximum voltage rating of 240VAC, it is fully compatible with 208Y/120VAC systems. It maintains its maximum 100kA interrupting capacity (AIC) across both 208V and 240V applications.
Does the QJA221502 feature a push-to-trip mechanism?
Yes, PowerPacT Q-frame breakers include a push-to-trip button on the faceplate. This allows electricians to manually trip the breaker to verify the mechanical operation of the trip mechanism during routine maintenance.
Is the QJA221502 rated for HVAC applications?
Yes, this breaker is HACR rated, meaning it is approved for use with heating, air conditioning, and refrigeration equipment that requires dedicated circuit protection.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.