Skip to main content

ABB S281UC-K1 Miniature Circuit Breaker

  • 1A
  • 1 Pole
  • DIN Rail
ABB S281UC-K1
Miniature Circuit Breaker
Brand ABB
SKU S281UC-K1
Select Item Condition
Earn 35 SuperPoints
  • 1A
  • 1 Pole
  • DIN Rail

Quantity

Bulk Pricing
Send your parts list for a volume quote.
ABB S281UC-K1 1 Pole Circuit Breaker

ABB S281UC-K1 - 1A 1 Pole Miniature Circuit Breaker

New

$35.95 No Stock

Quantity

Description

Designed for demanding industrial control applications, the S280UC series provides versatile UL 1077 supplementary protection. This 1A, single-pole breaker safely handles both AC and DC voltages with a specialized K-curve trip. It mounts securely onto standard DIN rail enclosures. As a legacy component, it serves as an exact replacement for older systems, while new builds use the S201MUC-K1. To safely interrupt DC faults, it incorporates a permanent magnet for rapid arc extinguishing.

Specifications

Key specifications
Brand ABB
Part Number S281UC-K1
Series S280UC
Amperage 1A
Poles 1
Mounting Style DIN Rail
Voltage 277VAC, 250VDC
Phase 1
AIC Rating 10kA @ 277VAC, 4.5kA @ 250VDC
Fit and installation
Terminal Type Box Lugs
For Use With DIN Rail Enclosures, Control Panels
Wire Gauge 18-4 AWG
Max Wire 4 AWG
Min Wire 18 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Curve K
Trip Adjustability Fixed
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Busbar System
Standards CSA C22.2 No. 235, IEC 60947-2, UL 1077, VDE 0660
Approval CE, CSA, IEC, UL, VDE
Temp Rating -25C to 55C
Construction Features Current Limiting

Product FAQs

7 answers
What makes the ABB S280UC series different from standard miniature circuit breakers?

The S280UC series is designed for universal current (UC) applications, safely handling both AC and DC voltages. It features a built-in permanent magnet that forces the rapid extinguishing of electrical arcs during DC faults.

Does polarity matter when installing the ABB S281UC-K1 in a DC circuit?

Yes. Because this breaker uses a permanent magnet to extinguish DC arcs, you must strictly observe the correct polarity and current flow direction during installation. Reversing the polarity can prevent the breaker from safely clearing a DC fault.

What does the K trip curve indicate on the S281UC-K1?

The K curve is engineered for loads with high inrush currents, such as motors and transformers. It allows the breaker to ride through momentary surges by tripping at 10 to 14 times the rated current, preventing nuisance tripping.

Is the ABB S281UC-K1 suitable for new panel builds?

While the S281UC-K1 serves as an exact replacement for legacy systems, ABB recommends the S201MUC-K1 for new installations requiring 1-pole, 1A universal current protection.

What standards does the ABB S281UC-K1 meet for circuit protection?

This breaker is a UL 1077 recognized supplementary protector. It is intended for use within equipment or appliances where branch circuit overcurrent protection is already provided or is not required.

Can the S281UC-K1 be used to protect sensitive semiconductor devices?

No. The K curve is designed for high inrush loads. For sensitive electronics and semiconductors, a Z curve breaker is required because it has a much lower instantaneous trip threshold.

Does the S281UC-K1 offer protection against accidental contact?

Yes, the breaker features extended, insulated terminals that provide an IP20 protection rating. This finger-safe design helps prevent accidental contact with live electrical components during maintenance.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.