A reliable solution for industrial power, the ABB XT1HU3025AYD000XXX is a 3-pole, 25A molded case circuit breaker. It utilizes fixed thermal and magnetic trip settings (LI) to protect commercial electrical systems. Designed for unit-mount installations, it integrates seamlessly into ABB ReliaGear NeXT panelboards and serves as an upgrade for legacy Tmax T1 series breakers. This 65kAIC rated breaker is current-limiting, HACR rated, and comes with line and load lugs and phase barriers.
Shunt Trip, Auxiliary Switch, Undervoltage Release, Motor Operator, Padlock Attachment
Accessories
Line and Load Lugs Included, Mounting Hardware, Phase Barriers
Standards
CSA C22.2 No. 5, IEC 60947-2, UL 489
Approval
CE, CSA, cULus, IEC, UL
Temp Rating
-25C to 70C
Construction Features
HACR Rated, Current Limiting, Reverse Feed, Double Insulated
Product FAQs
8 answers
What panelboards are compatible with the XT1HU3025AYD000XXX?
This XT1 frame breaker is designed for use with ABB ReliaGear NeXT Panelboards. It features a unit mount configuration for standard panel installations.
What wire sizes are accepted by the lugs on this breaker?
The factory-installed lugs accept wire gauges from 10 AWG up to 2/0 AWG. They are rated for both copper (Cu) and aluminum (Al) conductors.
What does the LI trip function indicate on this Tmax XT breaker?
The LI designation means the thermal-magnetic trip unit provides Long-Time (L) protection for overloads and Instantaneous (I) protection for short circuits.
Are the thermal or magnetic trip settings adjustable on this model?
No. This specific XT1 breaker features fixed thermal and fixed magnetic trip settings.
Is the XT1HU3025AYD000XXX suitable for direct current systems?
Yes, this breaker is rated for DC applications up to 250VDC, where it provides a 50kA interrupting rating.
Does this breaker include ground fault equipment protection?
No, it is equipped with a standard thermal-magnetic LI trip unit. It does not provide ground fault protection.
How is the XT1HU3025AYD000XXX mounted in an electrical enclosure?
It is a unit mount breaker, meaning it secures directly to the chassis or mounting pan with hardware rather than plugging onto a busbar.
How does the interrupting rating change based on system voltage?
The breaker provides 65kAIC for 480VAC systems, but the interrupting capacity increases to 100kAIC when installed on 240VAC systems.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.