Delivering 20 amps of protection, the ABB XT1NU3020AYD000XXX is a 3-pole molded case circuit breaker from the Tmax XT1N family. This configuration is tailored for ABB ReliaGear NeXT panelboards. It includes a line side connector and load side lugs, serving as a direct replacement for legacy T1N020TW breakers. The unit boasts a 25kAIC interrupt rating at 480VAC. Its fixed thermal-magnetic trip system ensures consistent performance, while the included lugs accept 10-2/0 AWG wire.
Line Side Connector, Load Side Lugs Included, Mounting Hardware
Standards
CSA C22.2 No. 5, IEC 60947-2, UL 489
Approval
CE, CSA, HACR, IEC, UL, cULus
Temp Rating
-25C to 70C
Construction Features
HACR Rated, Double Insulated, Reverse Feed
Product FAQs
7 answers
What wire sizes are compatible with the factory lugs on this ABB XT1 breaker?
The standard lugs accept 10 AWG to 2/0 AWG copper or aluminum conductors. Ensure proper torque specifications are met during installation.
What panelboards is the XT1NU3020AYD000XXX designed to fit?
It is primarily designed for ABB ReliaGear NeXT panelboards. As a unit mount breaker, it can also be installed in compatible standalone enclosures or switchboards that accept Tmax XT1 frames.
Are the trip settings adjustable on this 20A breaker?
No. It is equipped with a thermal magnetic trip unit that features fixed long-time thermal and fixed instantaneous magnetic trip settings.
Does this molded case breaker support direct current (DC) systems?
Yes, it is rated for use in DC applications, providing a 35kA interrupting capacity at both 250VDC and 500VDC.
How does the XT1NU3020AYD000XXX mount inside an enclosure?
This is a unit mount breaker. It bolts directly to the mounting pan or baseplate of the panelboard or enclosure, rather than plugging into a bus assembly.
What are the AC interrupting ratings for this specific Tmax XT1 model?
It offers a 50kA capacity at 240VAC, a 25kA capacity at 480VAC, and an 18kA capacity at 600VAC or 347VAC.
What does the LI designation mean on the trip unit?
The LI code indicates that the breaker provides Long-Time (L) protection for sustained overloads and Instantaneous (I) protection for immediate short circuit fault clearing.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.