Built for industrial power distribution, the ABB XT1NU3030AYD000XXX is a 3-pole, 30A molded case circuit breaker offering long-time and instantaneous (LI) protection. This unit mount MCCB installs into ABB ReliaGear neXT panelboards and SB switchboards. It serves as a direct replacement for legacy T1N030TW breakers, streamlining facility upgrades. Rated 50kAIC at 240V, this XT1 frame breaker features a current-limiting, reverse-feed capable design. Line and load lugs are included.
HACR Rated, Current Limiting, Reverse Feed, Double Insulated, Trip-Free Mechanism
Product FAQs
7 answers
Which panelboards and switchboards are compatible with the XT1NU3030AYD000XXX?
This XT1 frame breaker is designed for use with ABB ReliaGear neXT panelboards, ReliaGear SB switchboards, and Tmax XT enclosures. It utilizes a unit mount configuration rather than a plug-in design.
Is this breaker suitable for direct current (DC) systems?
Yes, the XT1NU3030AYD000XXX is rated for DC applications up to 500VDC, providing a 35kA interrupting capacity at both 250VDC and 500VDC.
What wire gauge range do the factory lugs on this breaker accept?
The included lugs accommodate wire sizes from 10 AWG up to 2/0 AWG. Ensure proper torque specifications are followed during installation as outlined in the ABB Tmax XT instruction manual.
Are the thermal and magnetic trip settings adjustable on this model?
No, this specific breaker features a fixed thermal and fixed magnetic trip unit. If your application requires adjustable trip settings, you will need to select an XT breaker equipped with an Ekip DIP or Ekip Touch electronic trip unit.
What does the N designation indicate in the XT1NU3030AYD000XXX part number?
The N specifies the interrupting capacity tier for the Tmax XT family. For the XT1 frame, the N tier provides a 25kAIC rating at 480VAC and 50kAIC at 240VAC.
Can the Tmax XT1 series be used to replace legacy General Electric breakers?
Yes, following ABB's acquisition of GE Industrial Solutions, the SACE Tmax XT family replaces legacy GE Spectra RMS and Record Plus molded case circuit breakers. The XT1 frame specifically serves as a modern replacement for the GE Record Plus FD frame and Spectra SE frame in many applications.
What does the LI trip function code mean on this breaker?
The LI designation indicates that the thermal magnetic trip unit provides Long-Time (L) protection against overloads and Instantaneous (I) protection against short circuits. Both of these settings are fixed on this specific model.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.