Built to handle demanding commercial loads, the ABB XT1NU3045AFD000XXX is a 45A, 3-pole molded case circuit breaker. It utilizes a fixed thermal-magnetic trip unit to deliver consistent LI protection. The breaker is fully compatible with ABB ReliaGear neXT panelboards, ReliaGear SB switchboards, and SACE Tmax XT enclosures, replacing older T1N045TL units. Delivering a 25kAIC interrupt rating at 480VAC, this HACR-rated device features reverse feed capability and includes load side lugs.
Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Padlock Attachment
Accessories
Load Side Lugs
Standards
CSA C22.2 No. 5, IEC 60947-2, UL 489
Approval
CE, CSA, HACR, IEC, UL, cULus
Temp Rating
-25C to 70C
Construction Features
HACR Rated, Reverse Feed, Double Insulated
Product FAQs
6 answers
Which panelboards are compatible with the XT1NU3045AFD000XXX?
This unit mounts directly into ABB ReliaGear neXT Panelboards, ReliaGear SB Switchboards, and SACE Tmax XT Panelboards. It requires the appropriate unit mount hardware kit for installation in these enclosures.
What does the N designation indicate in the XT1NU3045AFD000XXX catalog number?
The N indicates the Normal interrupting capacity tier for the SACE Tmax XT1 frame. For this specific frame size, the Normal tier provides a 25kA short circuit rating at 480VAC.
What are the acceptable wire sizes for the factory-installed lugs?
The standard lugs accept wire gauges from 10 AWG up to 2/0 AWG. They are rated for use with both copper (Cu) and aluminum (Al) conductors.
Is the trip unit on this 45A breaker adjustable?
No. This model features a fixed thermal and fixed magnetic trip unit. Both the long-time (L) overload and instantaneous (I) short-circuit protection settings are factory set and cannot be adjusted in the field.
Can the XT1NU3045AFD000XXX be utilized in DC circuits?
Yes, it is rated for DC applications up to 500VDC. When installing in DC systems, you must route the conductors through multiple poles in series according to ABB wiring guidelines to safely achieve the full voltage rating.
Does this breaker provide ground fault protection?
No. The LI trip function code indicates it provides Long-Time and Instantaneous protection only. It does not include integral equipment ground fault (G) protection.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.