Providing reliable overcurrent protection alongside remote shut-off functionality, this 20-amp single-pole breaker features a built-in 120V shunt trip. It installs quickly into Eaton Type CH load centers, occupying a standard 3/4-inch space. The device incorporates a highly visible trip indicator flag for rapid troubleshooting, and carries both HACR and SWD ratings, making it suitable for air conditioning systems and standard switching duties.
What panels accept the Eaton CHF120ST circuit breaker?
This 3/4-inch plug-on breaker is exclusively compatible with Eaton and Cutler-Hammer Type CH loadcenters. It will not fit in Type BR or other 1-inch panel designs.
What is the purpose of the shunt trip on the CHF120ST?
The built-in 120V shunt trip allows the breaker to be opened remotely via an external voltage signal. This is commonly used for emergency stops, fire alarm integration, or automated equipment disconnects.
What wire sizes and types are approved for the CHF120ST terminals?
The box lugs accept a single 14 to 8 AWG copper or aluminum conductor, or two 14 to 10 AWG copper or aluminum conductors.
What is the temperature rating for conductors connected to this breaker?
The terminals are rated for use with 60°C or 75°C copper or aluminum wire.
How does the trip flag function on the CHF series breakers?
The CHF120ST features a mechanical trip indicator flag that provides a clear visual distinction between a breaker that has tripped due to a fault and one that has been manually switched to the OFF position.
How does the thermal-magnetic trip mechanism operate on this breaker?
The fixed long-time and instantaneous (LI) trip functions use a bimetallic strip to delay tripping on mild overloads, preventing nuisance trips, while the magnetic element reacts immediately to severe short-circuit faults.
Is the CHF120ST rated for switching duty and HVAC applications?
Yes, it carries both SWD (Switching Duty) and HACR ratings, making it suitable for switching 120V fluorescent lighting loads and protecting heating, air conditioning, and refrigeration equipment.
What is the UPC for the Eaton CHF120ST?
The standard UPC for this shunt trip breaker is 786685384818.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 4.9 out of 5 based on 45 reviews.
4.9
Rated 4.9 out of 5 stars
Based on 45 reviews
5
Rated out of 5 stars
44
Total 5 star reviews: 44
4
Rated out of 5 stars
0
Total 4 star reviews: 0
3
Rated out of 5 stars
0
Total 3 star reviews: 0
2
Rated out of 5 stars
0
Total 2 star reviews: 0
1
Rated out of 5 stars
1
Total 1 star reviews: 1
Reviews Summary
Generated by AI from 44 most recent customer reviews
Last updated 3/6/26
Customers say these breakers work perfectly and fit exactly as described. Many reviews mention the company stocks hard-to-find parts that local hardware stores don't carry. Users appreciate the competitive pricing, often noting costs are lower than big box stores. Fast shipping and delivery times consistently exceed expectations. The ordering process is described as simple and straightforward. Customers frequently mention they will use the service again and recommend it to others. One negative review cited delayed fulfillment and high return fees affecting their business operations.
Product is fine but customer service is not great!
I needed these breakers for an install - first time using the company. They said they had them in stock. Took over a week to fulfil the order and it was 11 or 12 days before I had my hands on them. Tough on my business. Then when I went return them they hit me with so many fees that I was gonna net under $30 on a $104 order. It's too bad this was my first experience with them. I'll be sure to tell my electricians and project managers to never use this company. Short sighted. They won the battle but lost the war with a potential great long term client.