Eaton / Cutler-HammerEGB3045FFG
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | EGB3050FFG |
| Series | EGB |
| Amperage | 50A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 25kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | EG |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Series G Enclosures, Switchboards, MCCs, Pow-R-Line Panelboards |
| Wire Gauge | 14-1/0 AWG |
| Max Wire | 1/0 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Handle Mechanism |
|---|---|
| Accessories | Line and Load Terminals |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CE, CSA, IEC, KEMA, UL |
| Temp Rating | 40C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | EGB |
| Amperage | 50A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 25kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | EG |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Series G Enclosures, Switchboards, MCCs, Pow-R-Line Panelboards |
| Wire Gauge | 14-1/0 AWG |
| Max Wire | 1/0 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Handle Mechanism |
|---|---|
| Accessories | Line and Load Terminals |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CE, CSA, IEC, KEMA, UL |
| Temp Rating | 40C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed |
Eaton / Cutler-HammerEGB3045FFG
Eaton / Cutler-HammerEGB3060FFG
Eaton / Cutler-HammerEGB3040FFG
Eaton / Cutler-HammerEGB3035FFG
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | EGB3050FFG |
| Series | EGB |
| Amperage | 50A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 25kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | EG |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Series G Enclosures, Switchboards, MCCs, Pow-R-Line Panelboards |
| Wire Gauge | 14-1/0 AWG |
| Max Wire | 1/0 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Handle Mechanism |
|---|---|
| Accessories | Line and Load Terminals |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CE, CSA, IEC, KEMA, UL |
| Temp Rating | 40C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed |
This EG-frame breaker is designed for use in Eaton Pow-R-Line panelboards, including the PRL1a, PRL2a, PRL3a, and Pow-R-Line Xpert series. It is also compatible with Eaton Series G enclosures, motor control centers (MCCs), and switchboards.
The "FFG" suffix indicates that the breaker has a fixed thermal and fixed magnetic trip unit (FF) and comes standard with both line and load lugs installed (G).
The standard line and load lugs accept copper or aluminum (Cu/Al) wire sizes ranging from 14 AWG up to 1/0 AWG.
Yes, this thermal-magnetic breaker is rated for use in DC systems up to 250VDC, providing an interrupting capacity of 10 kAIC.
These prefixes indicate the interrupting capacity of the Eaton Series G EG-frame breakers. The EGB is the standard tier, rated at 18 kAIC at 480VAC. The EGE, EGS, and EGH models offer progressively higher interrupting ratings for systems with higher available fault currents.
No, this breaker features a fixed thermal and fixed magnetic trip unit. The long-time and instantaneous trip functions are factory set and cannot be adjusted in the field.
This is a unit mount, feed-thru circuit breaker. It is designed to be bolted directly to a backpan or mounting surface and features lugs on both the line and load sides for wire connections.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.