Eaton/Cutler-Hammer GFCB240 2 Pole Circuit Breaker

Eaton / Cutler-Hammer GFCB240 - 40A GFCI Miniature Circuit Breaker

New

$173.60 In Stock

Quantity

Similar Items

Description

Rated for 40 amps at 120/240VAC, the Eaton GFCB240 provides essential ground-fault protection. It features a 5mA trip sensitivity to meet NEC requirements for areas prone to moisture. This two-pole plug-on breaker installs into Eaton BR, Bryant, Challenger, and Westinghouse load centers. It crosses to the BRN240GF and is replaced by the GFTCB240. The unit includes a pigtail neutral connection and delivers a standard 10kAIC interrupting rating for reliable thermal-magnetic protection.

Specifications

Key specifications
Brand Eaton / Cutler-Hammer
Part Number GFCB240
Series GFCB
Amperage 40A
Poles 2
Mounting Style Plug-On
Voltage 120/240VAC
Phase 1
AIC Rating 10kA @ 120/240VAC
Fit and installation
Frame Type BR
Terminal Type Box Lugs
For Use With Eaton BR Load Centers, Bryant Load Centers, Challenger Load Centers, Westinghouse Load Centers
Wire Gauge 14-4 AWG (Cu/Al)
Max Wire 4 AWG
Min Wire 14 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LIG
Trip Function Long-Time, Instantaneous, Ground Fault
Trip Adjustability Fixed
Standards and features
Special Classification GFCI
Available Options Padlock Attachment
Accessories Pigtail Neutral
Standards CSA C22.2 No. 144, UL 489, UL 943
Approval CSA, UL
Temp Rating 40C
Construction Features Common Trip, HACR Rated

Product FAQs

6 answers
What load centers are compatible with the GFCB240 breaker?

This plug-on breaker is designed for use in Eaton BR, Bryant, Challenger, and Westinghouse load centers. It is not compatible with Eaton CH series panels.

What level of ground fault protection does the GFCB240 provide?

It provides Class A ground fault protection with a 5mA trip sensitivity, meeting NEC requirements for personnel protection in wet or damp locations.

Does the GFCB240 require a neutral wire connection?

Yes, this breaker features a pigtail neutral wire that must be connected directly to the neutral bus bar in your panel for the ground fault protection to function correctly.

Is the GFCB240 suitable for hot tub and spa installations?

Yes, this 40-amp, 2-pole GFCI breaker is commonly used to provide the required Class A ground fault protection for hot tubs, spas, and pool equipment.

What is the difference between the GFCB240 and the GFTCB240?

The GFCB240 is the standard ground fault breaker, while the GFTCB240 is the newer version that includes an automatic self-test feature to ensure the GFCI circuitry is functioning properly. The GFTCB240 serves as a direct replacement.

What wire sizes can be used with the load terminals on this breaker?

The box lugs accept 14 AWG to 4 AWG copper or aluminum wire. This range easily accommodates the 8 AWG or 6 AWG wire typically required for 40-amp circuits.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.

Reviews

5.0
Rated 5.0 out of 5 stars
Based on 4 reviews
Total 5 star reviews: 4
Total 4 star reviews: 0
Total 3 star reviews: 0
Total 2 star reviews: 0
Total 1 star reviews: 0
Rating
Ratings
4 reviews
  • AM
    Alayna M.
    Verified Buyer
    I recommend this product
    Rated 5 out of 5 stars
    8/12/26
    Works great already installed

    Needed to replace a bad breaker, this one was difficult to find but you had in on hand. Already installed and being used.

  • JF
    Joseph F.
    Flag of United States
    I recommend this product
    Rated 5 out of 5 stars
    9/8/21
    exactly what I needed, thank

    exactly what I needed, thank you. You well the only supplier that stocked this item

  • JB
    Joe B.
    Flag of United States
    I recommend this product
    Rated 5 out of 5 stars
    5/29/19
    Fast and Painless

    Inline order easy and fast. Shipping fast. Got what I wanted.

  • AL
    Alan L.
    Flag of United States
    I recommend this product
    Rated 5 out of 5 stars
    3/9/19
    Equipment Service Honda North America

    Great experience, easy to order, rec’d in timely manner.