Description

The LDC3450 is a 3-pole, 450A MCCB from Eaton's Series C family. Built for industrial power distribution, this L-frame device provides reliable overcurrent protection. This unit-mount breaker integrates with Pow-R-Line 4 panelboards, switchboards, and motor control centers. It includes standard lugs for 3/0 AWG to 350 kcmil wire. Delivering 200kAIC at 240V, it utilizes thermal-magnetic trip technology with adjustable magnetic settings. The current-limiting design is HACR rated.

Specifications

Key specifications
Brand Eaton / Cutler-Hammer
Part Number LDC3450
Series LDC
Amperage 450A
Poles 3
Mounting Style Unit Mount
Voltage 240VAC, 480VAC, 600VAC, 250VDC
Phase 3
AIC Rating 200kA @ 240VAC, 100kA @ 480VAC, 50kA @ 600VAC, 22kA @ 250VDC
Fit and installation
Frame Type LDC
Terminal Type Lugs
For Use With Eaton Pow-R-Line 4 Panelboards, Switchboards, Motor Control Centers
Wire Gauge (2) 3/0 AWG - 350 kcmil (Al/Cu)
Max Wire 350 kcmil
Min Wire 3/0 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Adjustable Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment
Accessories Line and Load Lugs (TA602LD)
Standards CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489
Approval CSA, UL
Temp Rating 40C
Construction Features Current Limiting, HACR Rated, High Interrupting Capacity, Trip-Free Mechanism, Visual Trip Indicator

Product FAQs

8 answers
What types of enclosures or panels is the LDC3450 compatible with?

This L-Frame breaker is designed for use in Eaton Pow-R-Line 4 panelboards, switchboards, and motor control centers. It is a unit mount breaker, meaning it bolts directly to the mounting surface rather than plugging onto a bus.

How does the thermal-magnetic trip unit function on this 450A breaker?

The LDC3450 features an interchangeable thermal-magnetic trip unit with LI (Long-Time and Instantaneous) functions. The thermal element for overload protection is fixed at 450A, while the magnetic element for short-circuit protection is adjustable to coordinate with other devices in the electrical system.

What wire size and material can be used with the standard lugs on the LDC3450?

The standard lugs accept two 3/0 AWG to 350 kcmil conductors per phase. The terminals are rated for both aluminum and copper wire.

Can the LDC3450 replace older Westinghouse or Cutler-Hammer L-Frame breakers?

Yes, Eaton Series C breakers are backward compatible. The LDC3450 can replace older Cutler-Hammer or Westinghouse LDC breakers with the same frame size and specifications.

What does the 200 kAIC rating at 240V mean for installation?

The 200 kAIC rating indicates the maximum fault current the breaker can safely interrupt at 240V AC without sustaining damage. This high interrupting capacity makes it suitable for commercial and industrial systems with high available fault currents. Note that the interrupting capacity drops to 100 kAIC at 480V AC and 50 kAIC at 600V AC.

Can the trip unit in the LDC3450 be swapped for a different amperage?

Yes, the LDC3450 features an interchangeable trip unit design. If the load requirements change, the trip unit can be replaced with a different Series C L-Frame trip unit without having to remove the entire breaker frame from the panelboard.

What safety precautions are required when adjusting the magnetic trip settings?

Adjustments to the magnetic trip settings should only be performed by a qualified electrician. The breaker must be de-energized, and settings should be calculated based on a formal coordination study to ensure proper system protection and arc flash safety.

Does the LDC3450 come with line and load lugs installed?

Yes, this feed-thru circuit breaker typically includes standard line and load lugs. Always verify lug torque specifications in the manufacturer instructions before energizing the panel to prevent thermal issues at the terminations.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.