Engineered for commercial safety, the Eaton QBGF2030 delivers 30 amps of reliable power with integrated 5mA ground fault protection. It helps facilities meet strict NEC code requirements for wet or damp locations. The bolt-on design ensures a secure, vibration-resistant connection within Eaton Pow-R-Line and Quicklag panelboards. Featuring a 10 kAIC interrupting rating at 120/240V, this thermal-magnetic unit includes a visual trip indicator and is replaced by the QBGFT2030.
Shunt Trip, Auxiliary Switch, Bell Alarm, Padlock Attachment
Accessories
Load Side Lugs Included
Standards
HACR, UL 489, UL 943
Approval
CSA, UL
Temp Rating
40C
Construction Features
HACR Rated, Non-Interchangeable Trip, Common Trip, Visual Trip Indicator, Self-Test
Product FAQs
6 answers
Which panelboards accept the QBGF2030 breaker?
This breaker is designed for installation in Eaton Pow-R-Line and Quicklag panelboards. It utilizes a bolt-on connection, which fastens directly to the panel chassis for a secure, vibration-resistant mount typical in commercial and industrial settings.
What level of ground-fault protection does the QBGF2030 provide?
This unit features a 5mA trip sensitivity. This Class A GFCI rating is specifically designed for personnel safety to meet National Electrical Code (NEC) requirements for wet or damp locations.
How do you connect the neutral on this GFCI breaker?
The QBGF2030 uses a pigtail neutral design. During installation, the factory-installed white pigtail wire must be routed to the panelboard neutral bus bar, while the circuit's load neutral connects directly to the breaker itself.
What wire gauges are supported by the load terminals?
The box lugs accept 14 to 10 AWG copper wire and 12 to 10 AWG aluminum wire. Always refer to the manufacturer torque specifications during field wiring to ensure a safe connection.
What is the self-testing equivalent to the QBGF2030?
The Eaton QBGFT2030 is the self-testing version of this breaker. The "T" in the catalog number indicates the addition of an auto-monitoring function to ensure the GFCI circuitry remains operational and compliant with updated safety standards.
What types of faults does the LIG trip function protect against?
The LIG designation indicates protection against three distinct fault conditions. Long-Time handles gradual thermal overloads, Instantaneous trips immediately during short circuits, and Ground-Fault detects small current leaks to ground for personnel safety.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 4.8 out of 5 based on 11 reviews.