Eaton / Cutler-HammerQBHW2015S
Quantity
New
Quantity
Eaton / Cutler-HammerQBHW2015S
Eaton / Cutler-HammerQBHW2030S
Eaton / Cutler-HammerQBHW2040S
Eaton / Cutler-HammerQBHW2050S
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | QBHW2020S |
| Series | QBHW |
| Amperage | 20A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 120/240VAC, 48VDC |
| Phase | 1 |
| AIC Rating | 22kA @ 120/240VAC, 5kA @ 48VDC |
| Frame Type | BAB |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | Eaton Pow-R-Line 1a Panelboards, Eaton Pow-R-Line 2a Panelboards |
| Wire Gauge | 14-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Load Side Lugs Included, Shunt Trip (Factory Installed) |
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip |
Although it is a 2-pole breaker, it requires three pole spaces in your panelboard. The factory-installed shunt trip mechanism occupies one additional pole space on the right side of the unit.
No. This is a bolt-on BAB-frame breaker designed specifically for commercial and industrial Eaton Pow-R-Line 1a and 2a panelboards. It will not fit in standard plug-on residential load centers.
The integrated shunt trip allows the breaker to be tripped remotely by applying a 120V signal to the shunt trip coil. This is commonly used for emergency stops, fire alarm integration, or remote equipment shutdown.
Yes, the box lugs are rated for both copper and aluminum conductors ranging from 14 AWG to 4 AWG. Ensure you apply an appropriate oxide inhibitor when terminating aluminum wire.
Yes. With its 22kAIC rating at 120/240V AC, this breaker exceeds standard 10kAIC and 14kAIC requirements, making it fully suitable for systems requiring those lower fault current ratings.
Yes, in addition to its AC ratings, the QBHW2020S is rated for up to 48V DC with an interrupting capacity of 5kAIC, making it suitable for specific low-voltage DC control circuits.
Both are bolt-on breakers for Pow-R-Line panelboards, but they differ in interrupting capacity. The QBHW series is rated for 22kAIC at 120/240V AC, whereas the standard BAB series is rated for 10kAIC.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.