The Eaton HKD3400F circuit breaker frame is rated 400A with 3 poles. Voltage ratings are 240VAC, 480VAC, 600VAC and 250VDC, with interrupting ratings of 100kA, 65kA, 35kA and 22kA, respectively. This Series C HKD model uses K Frames, panel mounting and lug terminals. Approvals include CE, CSA and UL. This listing is the frame only. A compatible trip unit is required and is not included.
Specifications
Key specifications
For Use With
Eaton Series C Panelboards, Switchboards, Motor Control Centers
Mounting Type
Panel Mount
Standards
CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489
Voltage
240VAC, 480VAC, 600VAC, 250VDC
Electrical ratings
Amperage
400A
Poles
3
Phase
3
Interrupting Rating
100kAIC at 240VAC, 65kAIC at 480VAC, 35kAIC at 600VAC, 22kAIC at 250VDC
Fit and installation
Terminal Connection
Lugs
Standards and features
Approval
CE, CSA, UL
Temperature Rating
40C
Product details
Series
HKD
Brand
Eaton / Cutler-Hammer
MPN
HKD3400F
UPC
786679661956
Product FAQs
6 answers
How do I select the Eaton HKD3400F for available fault current on an AC system?
Its interrupting ratings are 100kA at 240VAC, 65kA at 480VAC, and 35kA at 600VAC. Select the rating for your system voltage and ensure the available fault current at the installation point does not exceed it.
What rating should I use when evaluating this frame for a DC circuit?
For a 250VDC circuit, use the 22kA interrupting rating. Compare that rating with the available fault current at the installation point rather than using an AC interrupting rating.
Why does the HACR rating matter for an HVAC application?
HACR means heating, air-conditioning, and refrigeration. The HACR rating is relevant when equipment requirements call for HACR-rated circuit protection, so include it when checking the equipment's electrical protection requirements.
What does the lug terminal type mean for installation?
Lug terminals secure the conductor ends at the electrical connection. Plan conductor routing so the conductors can enter the lugs without strain and remain accessible for termination work.
Which standards and approvals should I consider during project review?
The frame carries CE, CSA, and UL approvals, with standards including CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, and UL 489. Compare these with the project's required standards and approvals when selecting circuit protection.
How should I use the 400A frame rating during selection?
The Eaton HKD3400F has a 400A frame amperage rating. Use that rating as a frame-selection parameter when reviewing the circuit's current requirements.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 5.0 out of 5 based on 4 reviews.