Designed to safeguard 20A branch circuits in damp environments, this device provides reliable personnel protection. The integrated self-test feature periodically checks internal electronics. Engineered as a universal solution, it mounts into competitor one-inch load centers such as Square D Homeline and Crouse-Hinds. It acts as an upgrade for legacy CL120GF components. Operating with a 10kAIC rating, the breaker includes a pigtail neutral and a trip-to-center handle mechanism.
General Electric, Siemens, Murray, Square D Homeline, Crouse-Hinds, Thomas & Betts Load Centers
Wire Gauge
14-8 AWG
Max Wire
8 AWG
Min Wire
14 AWG
Protection and operation
Trip Technology
Thermal Magnetic
Trip Function Code
LIG
Trip Function
Long-Time, Instantaneous, Ground Fault
Trip Adjustability
Fixed
Standards and features
Special Classification
GFCI
Accessories
Pigtail Neutral
Standards
NEC Article 240.7, UL 489, UL 943
Approval
UL, UL Classified
Temp Rating
40C
Construction Features
Classified for use in Square D Homeline, Siemens, GE Panelboards, Self-Test, Trip-to-Center
Product FAQs
6 answers
Which competitor load centers is the Eaton CLGF120 UL classified to be installed in?
This 1-inch classified breaker is UL approved for use in General Electric, Siemens, Murray, Square D Homeline, Crouse-Hinds, and Thomas & Betts load centers.
What level of ground fault protection does the CLGF120 provide?
It provides Class A ground fault protection, designed to trip when it detects a current leakage of 5mA to protect personnel from electrical shock. It also includes self-testing capabilities.
How is the neutral connection wired for this breaker?
The CLGF120 features a pigtail neutral wire that must be connected directly to the neutral bus bar in the panel to ensure proper ground fault monitoring.
Does the circuit neutral need to connect to the breaker?
Yes, the load neutral wire from the branch circuit must be landed on the breaker's neutral terminal for the GFCI circuitry to function correctly.
Can the CLGF120 be used as a direct replacement for competitor GFCI breakers?
Yes, as a UL classified replacement breaker, it is tested and approved to safely replace 20A single-pole GFCI breakers in compatible 1-inch load centers, including Square D Homeline and Siemens panels.
Does this breaker provide visual trip indication?
Yes, it features a trip-to-center handle position that provides clear visual confirmation when the breaker has tripped due to an overcurrent or ground fault event.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.