Built for circuit protection, the Eaton PDF53M1200E3MN is a 3-pole, 3-phase molded case circuit breaker rated 1200A and 600VAC. Its interrupting rating is 65kA at 480VAC. The Power Defense 5-Frame design uses unit mounting with no lugs. Adjustable electronic LSIG tripping provides long-time, short-time, instantaneous and ground-fault protection. It carries CSA, IEC, UL and CCC approvals and meets RoHS standards.
How should I use the 1200A rating when selecting the Eaton PDF53M1200E3MN?
The 1200A rated current is a starting point for matching the breaker to the circuit's load and conductor protection requirements. Evaluate it together with the adjustable trip settings when planning overcurrent protection.
How does the 600VAC rating guide circuit selection?
The 600VAC rating guides selection by AC system voltage. Check voltage suitability separately from interrupting capacity, which must be evaluated at the applicable system voltage.
How do I apply the 65kA interrupting rating at 480VAC?
For a 480VAC installation, compare the available fault current at the installation point with the 65kA interrupting rating. The available fault current must not exceed that rating.
What protection does the LSIG trip function offer?
LSIG provides long-time, short-time, instantaneous and ground-fault protection functions. These address sustained overloads, short circuits and ground faults, giving you multiple protection functions to consider in the circuit protection plan.
What does an adjustable electronic trip mean for commissioning?
An electronic trip evaluates current electronically to control tripping. Adjustability lets you configure protection settings for the circuit, so commissioning should include setting and verifying the trip settings against the protection plan.
How do the three poles relate to a three-phase circuit?
The breaker has three poles for a three-phase circuit, giving each phase its own pole. Plan the phase conductor routing and terminations around that three-pole arrangement.
What does the no-lugs terminal connection mean for installation planning?
The breaker has no terminal lugs. Plan the conductor termination method before installation rather than assuming lug-based connections are included.
What mounting style and dimensions should I use for mechanical layout?
Use the unit-mount construction and 5-Frame physical frame when planning the mounting arrangement. The breaker body measures 16 in high, 8.25 in wide and 5.5 in deep; use those dimensions to plan its space allocation and conductor routing.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 5.0 out of 5 based on 2 reviews.