Eaton PDG22P0100TFFL molded case circuit breaker is rated 100A with 2 poles and a 100kA interrupting rating at 480VAC. This Power Defense PDG2 breaker has a 2-Frame physical frame, fixed thermal and fixed magnetic trips, and LI trip function. It features panel mounting, a load side lug connection and a 14-1/0 AWG conductor range. Dimensions are 6 in high, 2.75 in wide and 3.50 in deep.
How should I select the 100A rating of the Eaton PDG22P0100TFFL?
This breaker has a 100A rated current. Select it by coordinating the circuit load, conductor ampacity and applicable electrical code requirements, rather than matching the load current alone.
Which circuit voltages can I select this breaker for?
The rated voltages are 240VAC, 480VAC, 600VAC and 250VDC. Match the circuit voltage and AC or DC operation to the applicable rating when selecting the breaker.
How does the 100kA interrupting rating affect selection for a 480VAC circuit?
At 480VAC, this breaker has a 100kA interrupting rating. Select it where the available fault current at the installation point does not exceed 100kA.
Can I adjust the overload or instantaneous trip settings?
No. Both the thermal and magnetic trip settings are fixed. The thermal-magnetic LI trip provides time-delayed overload protection and instantaneous short-circuit protection, so select it for circuits suited to fixed trip settings.
What conductor sizes can I terminate at the load-side lug?
The load-side lug accepts conductors from 14 AWG through 1/0 AWG. Choose a conductor within that terminal range while also meeting the circuit's ampacity requirements; terminal acceptance alone does not determine conductor sizing.
What dimensions should I use when planning installation space?
The breaker body is 6.00 in high, 2.75 in wide and 3.50 in deep. Use these dimensions when planning the layout, with space for conductor routing and access to the load-side lug.
What does the two-pole construction mean when selecting a breaker?
The Eaton PDG22P0100TFFL has two poles, providing overcurrent protection for two circuit conductors. Pole count guides selection according to how many conductors require protection.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.