Built to protect circuits against overloads and short circuits, the Eaton PDG23M0150VFFL is a molded case circuit breaker. It is rated 150A and 600VAC, with 3 poles and a 65kA interrupting rating at 480VAC. Part of the PDG2 series, it has a load side lug terminal connection. Its thermal magnetic trip has fixed thermal and fixed magnetic settings, with LI providing long-time and instantaneous protection.
How should I use the 150A rating when selecting the Eaton PDG23M0150VFFL?
Use its 150A rated current to evaluate the circuit's load requirements and conductor protection. Coordinate breaker selection with the conductor ampacity and applicable load-sizing requirements.
How does the 600VAC rating guide circuit selection?
The 600VAC rating sets the rated voltage limit for AC circuit selection. Check the interrupting rating separately at the circuit's operating voltage.
What does the 65kA interrupting rating mean for a 480VAC installation?
The breaker is rated to interrupt fault current up to 65kA at 480VAC. For a 480VAC application, the available fault current at the installation point must not exceed that rating.
When should I select this three-pole breaker?
Select it for a three-phase circuit requiring breaker protection on all three phase conductors. Its three-pole configuration guides the circuit arrangement and conductor routing.
How does the thermal-magnetic LI trip protect the circuit?
LI protection combines long-time overload protection with instantaneous short-circuit protection. The thermal element responds to sustained overloads, while the magnetic element responds rapidly to high fault current.
Can I adjust the thermal or magnetic trip settings?
Both the thermal and magnetic trip settings are fixed. Select this breaker when circuit protection coordination calls for fixed trip settings rather than field-adjustable settings.
What does the load-side lug connection mean for installation?
The load-side connection uses a lug to terminate the outgoing conductor. Plan the load-side wiring route and access so the conductor can be positioned and secured at the lug.
What dimensions should I use when laying out the breaker?
The breaker measures 6 in high, 4.12 in wide and 3.5 in deep. Use these dimensions to plan its physical footprint, allowing room for wiring access in your layout.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.