Built for circuit protection, the Eaton PDG53M0800E5MN molded case circuit breaker is rated 800A and 600VAC with 3 poles and 3-phase operation. This Power Defense 5-Frame breaker has an interrupting rating of UL 489 65kA at 480VAC. Its adjustable electronic LSIG trip provides long-time, short-time, instantaneous and ground-fault protection. It measures 16 in high and 5.50 in deep and has no lugs.
How should I use the 800A rating when selecting this breaker?
The Eaton PDG53M0800E5MN has an 800A rated current. Use that rating when evaluating load requirements and conductor ampacity, and coordinate the adjustable trip settings with the circuit's protection requirements.
How does the 600VAC voltage rating guide selection?
The rated voltage is 600VAC. Select it for a circuit voltage within that rating, and evaluate interrupting capacity separately at the operating voltage.
How do I apply the 65kA interrupting rating at 480VAC?
The UL 489 interrupting rating is 65kA at 480VAC. For a 480VAC installation, compare the available fault current at the installation point with this rating; it must not exceed 65kA.
What does the adjustable electronic trip offer when setting up protection?
The electronic trip allows protection settings to be adjusted rather than relying solely on fixed trip behavior. Set it according to the protected circuit's requirements and the intended coordination with other protective devices.
What protection functions does LSIG include?
LSIG includes long-time overload, short-time, instantaneous and ground-fault protection. These functions address sustained overloads, high-current faults with timed or instantaneous response, and faults to ground, helping guide protection coordination.
What should I plan for with the No Lugs terminal connection?
This breaker has no lugs, so conductor termination needs to be addressed during installation planning. Resolve the termination method before beginning conductor installation.
How much space should I allow for the breaker body?
The breaker measures 16.00 in high, 8.25 in wide and 5.50 in deep. Use these dimensions when laying out the installation, and account separately for conductor routing and working space.
When should I select the three-pole configuration?
This is a three-pole breaker for three-phase applications. Choose this configuration when the circuit requires interruption across all three phases.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.