Eaton PDG63P2500E4MN molded case circuit breaker from the Power Defense family and PDG6 series is rated 2500A and 600VAC, with 3 poles, 3-phase operation and a 100kA interrupting rating at 480VAC. This 6-Frame breaker features an adjustable electronic PXR 20 trip unit with LSI trip function, panel mounting, no lugs and standard protection. It measures 16 in high, 15.5 in wide and 9.75 in deep. Approvals include CSA, IEC, UL, CCC and CE; standards include RoHS.
How should I use the 2500A current rating when selecting the Eaton PDG63P2500E4MN?
The breaker has a rated current of 2500A. Evaluate that rating together with the calculated load, conductor ampacity and intended trip settings when selecting circuit protection.
What does the 600VAC voltage rating mean for selection?
The 600VAC rating guides selection for the circuit's operating voltage. Check the interrupting rating separately, since voltage rating and fault-interruption capability serve different purposes.
How do I apply the 100kA interrupting rating at 480VAC?
At 480VAC, the breaker has a 100kA interrupting rating. Compare the available fault current at the installation point with that rating so it does not exceed the breaker's fault-interruption capability.
What does the three-pole configuration mean for circuit selection?
This is a three-pole breaker for three-phase service. Use the pole count when planning protection of the three phase conductors.
What protection functions does the LSI trip provide?
LSI means long-time, short-time and instantaneous protection. These functions address sustained overloads and fault currents with different response timing, helping guide protection and coordination planning.
How does the adjustable electronic trip affect setup?
The PXR 20 electronic trip unit is adjustable, allowing protection settings to be selected for the circuit rather than relying on fixed trip behavior. Set it according to the load, conductor protection needs and coordination plan.
What should I account for with the no-lug terminal connection?
The breaker has a no-lug terminal connection. Include conductor termination planning in the installation design rather than planning around a lug-equipped connection.
What dimensions should I use for equipment layout?
The breaker measures 16 in high, 15.5 in wide and 9.75 in deep. Use these dimensions to account for the breaker's physical size when laying out the equipment.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.