| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | EGC |
| Amperage | 60A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600Y/347VAC, 125/250VDC |
| Phase | 3 |
| AIC Rating | 200kA @ 240VAC, 100kA @ 480VAC, 35kA @ 600Y/347VAC, 42kA @ 125/250VDC |
| Frame Type | EG |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Series G Panelboards, Pow-R-Line Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | 14-1/0 AWG |
| Max Wire | 1/0 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator, Rotary Handle, Handle Lock |
|---|---|
| Accessories | Line and Load Terminals |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CE, CSA, IEC, KEMA KEUR, UL |
| Temp Rating | 40C |
| Construction Features | High Interrupting Capacity, High-Speed Blow-Open Action, Reverse Feed |
The first F indicates a fixed thermal trip, the second F indicates a fixed magnetic trip, and the G signifies that standard line and load lug terminals are included.
The difference is the interrupting capacity. The EGC frame offers the highest rating in this family at 100kAIC at 480VAC. For comparison, the EGB is 18kAIC, EGE is 25kAIC, EGS is 35kAIC, and EGH is 65kAIC.
This unit mount breaker is designed for installation in Eaton Series G panelboards, Pow-R-Line panelboards, switchboards, and motor control centers.
It is a unit mount, feed-thru circuit breaker. It bolts directly to the enclosure backpan or chassis rather than plugging into a busbar.
Yes, this breaker is rated for DC applications up to 125/250VDC, providing an interrupting capacity of 42kAIC.
The included line and load lugs accommodate copper or aluminum conductors ranging from 14 AWG to 1/0 AWG.
No, this breaker is equipped with a fixed thermal and fixed magnetic (LI) trip unit, meaning the trip settings cannot be adjusted in the field.
No. While some EG frame breakers allow it, Eaton specifies that EGC circuit breakers are not suitable for reverse line and load connections.
Yes, the EGC series features a current limiting design. It operates with a high-speed blow-open action to rapidly clear faults and reduce let-through current during a short circuit.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.