Eaton / Cutler-HammerFAZ-C15/3-NA
Quantity
New
Quantity
Eaton / Cutler-HammerFAZ-C15/3-NA
Eaton / Cutler-HammerFAZ-D13/3-NA
Eaton / Cutler-HammerFAZ-B15/3-NA
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | FAZ-D15/3-NA |
| Series | FAZ-NA |
| Amperage | 15A |
| Poles | 3 |
| Mounting Style | DIN Rail |
| Voltage | 480Y/277VAC, 96VDC |
| Phase | 3 |
| AIC Rating | 14kA @ 480Y/277VAC, 10kA @ 96VDC |
| Frame Type | FAZ |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | DIN Rail Systems, Industrial Control Panels |
| Wire Gauge | 18-6 AWG |
| Max Wire | 6 AWG |
| Min Wire | 18 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Curve | D |
| Trip Adjustability | Fixed |
| Available Options | Auxiliary Switch, Bell Alarm, Busbar System, Lockout Attachment, Padlock Attachment, Shunt Trip, Undervoltage Release |
|---|---|
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | ABS, CCC, CE, CSA, DNV, GL, IEC, Lloyd's, RoHS, UL, VDE |
| Temp Rating | -40C to 75C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed, Trip-Free Mechanism |
The D-curve provides a magnetic trip point of 10 to 20 times the rated current. It is designed for applications with high inrush currents, such as motors, transformers, and power supplies, to prevent nuisance tripping.
The NA suffix indicates that the breaker is UL 489 listed for branch circuit protection in North America, making it suitable for feeder and branch circuits rather than just UL 1077 supplementary protection.
The required torque depends on the wire size used. For 18 to 12 AWG wire, torque to 21 lb-in (2.4 Nm). For 10 to 8 AWG wire, torque to 25 lb-in (2.8 Nm). For 6 AWG wire, torque to 36 lb-in (4.0 Nm).
Yes, power to the FAZ-NA series circuit breakers can be fed from either the line or the load side.
Yes, it features a current-limiting design that interrupts fault currents within one-half cycle, reducing peak let-through energy to protect downstream equipment.
Yes, the FAZ-D15/3-NA is dual-rated for both AC and DC applications. It is rated for up to 96VDC with a 10kA interrupting capacity.
It mounts directly onto a standard 35mm DIN rail without the need for additional tools.
Yes, it features a trip-free design, meaning the breaker will still trip during an overcurrent or short-circuit event even if the handle is physically held in the ON position.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.