Part of the Series C family, this 225A F-Frame breaker utilizes a microprocessor-based Digitrip 310+ LSIG trip unit for precise coordination. It installs into Eaton Pow-R-Line C panelboards, switchboards, and motor control centers using a standard unit mount configuration. Delivering 65 kAIC interrupting capacity at 480VAC, the HFDE322536L offers advanced adjustable long-time, short-time, instantaneous, and ground fault protection for demanding industrial applications.
Digitrip 310+ Electronic Trip Unit (LSIG), Line and Load Terminals
Standards
CSA C22.2 No. 5, IEC 60947-2, NEMA AB-1, UL 489
Approval
CE, CSA, HACR, UL
Temp Rating
40C
Construction Features
HACR Rated, Reverse Feed, True RMS Sensing
Product FAQs
8 answers
Which panelboards are compatible with the HFDE322536L circuit breaker?
This F-frame breaker is designed for use in Eaton Pow-R-Line C Panelboards, Series C Panelboards, switchboards, and motor control centers.
Can the HFDE322536L be reverse fed?
Yes, Eaton FDE electronic circuit breakers are suitable for reverse-feed applications.
Is the HFDE322536L rated for DC voltage applications?
No, FDE electronic breakers do not carry DC ratings. If your application requires DC ratings, you must use a thermal-magnetic F-frame breaker instead.
Do I need an external neutral sensor for the ground fault function on this breaker?
Yes, if you are installing this breaker in a 3-phase, 4-wire system, an external neutral current sensor is required for the ground fault (G) protection to function correctly. The sensor is not included with the breaker.
What settings can be adjusted on the electronic LSIG trip unit?
The LSIG trip unit allows you to adjust the Long-Time pickup and delay, Short-Time pickup and delay, Instantaneous pickup, and Ground Fault pickup and delay settings to coordinate with your specific system requirements.
Can the HFDE322536L replace an older thermal-magnetic HFD breaker?
Yes, it shares the same physical F-frame footprint and can mount in the same space. However, because it uses an electronic LSIG trip unit, you must verify that your system supports the ground fault protection requirements, including adding a neutral sensor if used on a 4-wire system.
What type of wire connections are provided on the HFDE322536L?
This breaker includes feed-thru lugs on both the line and load sides. The terminals are rated for 4 AWG to 4/0 AWG copper or aluminum conductors.
Is the HFDE322536L HACR rated for HVAC applications?
Yes, all Eaton Series C F-frame circuit breakers are HACR rated for use with heating, air conditioning, and refrigeration equipment.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.