Eaton / Cutler-HammerNGS312032E
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | NGS312033E |
| Series | NGS |
| Amperage | 1200A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC |
| Phase | 3 |
| AIC Rating | 85kA @ 240VAC, 50kA @ 480VAC, 25kA @ 600VAC |
| Amperage Range | 500-1200A |
|---|
| Frame Type | NG |
|---|---|
| Terminal Type | Stud/Tapped Pad |
| For Use With | Eaton Series G Panelboards, Switchboards, Motor Control Centers |
| Max Wire | 500 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LS |
| Trip Function | Long-Time, Short-Time |
| Trip Adjustability | Adjustable |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lugs, Handle Lock, Rotary Handle |
|---|---|
| Accessories | Digitrip 310+ Trip Unit |
| Standards | CSA C22.2 No. 5, HACR Rated, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, HACR, IEC, KEMA KEUR, UL |
| Temp Rating | -20C to 70C |
| Construction Features | HACR Rated, Reverse Feed, 80% Rated, Zone Selective Interlocking |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | NGS |
| Amperage | 1200A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC |
| Phase | 3 |
| AIC Rating | 85kA @ 240VAC, 50kA @ 480VAC, 25kA @ 600VAC |
| Amperage Range | 500-1200A |
|---|
| Frame Type | NG |
|---|---|
| Terminal Type | Stud/Tapped Pad |
| For Use With | Eaton Series G Panelboards, Switchboards, Motor Control Centers |
| Max Wire | 500 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LS |
| Trip Function | Long-Time, Short-Time |
| Trip Adjustability | Adjustable |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lugs, Handle Lock, Rotary Handle |
|---|---|
| Accessories | Digitrip 310+ Trip Unit |
| Standards | CSA C22.2 No. 5, HACR Rated, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, HACR, IEC, KEMA KEUR, UL |
| Temp Rating | -20C to 70C |
| Construction Features | HACR Rated, Reverse Feed, 80% Rated, Zone Selective Interlocking |
Eaton / Cutler-HammerNGS312032E
Eaton / Cutler-HammerNGS312036E
Eaton / Cutler-HammerNGH312038E
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | NGS312033E |
| Series | NGS |
| Amperage | 1200A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC |
| Phase | 3 |
| AIC Rating | 85kA @ 240VAC, 50kA @ 480VAC, 25kA @ 600VAC |
| Amperage Range | 500-1200A |
|---|
| Frame Type | NG |
|---|---|
| Terminal Type | Stud/Tapped Pad |
| For Use With | Eaton Series G Panelboards, Switchboards, Motor Control Centers |
| Max Wire | 500 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LS |
| Trip Function | Long-Time, Short-Time |
| Trip Adjustability | Adjustable |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lugs, Handle Lock, Rotary Handle |
|---|---|
| Accessories | Digitrip 310+ Trip Unit |
| Standards | CSA C22.2 No. 5, HACR Rated, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, HACR, IEC, KEMA KEUR, UL |
| Temp Rating | -20C to 70C |
| Construction Features | HACR Rated, Reverse Feed, 80% Rated, Zone Selective Interlocking |
Yes, the Series G NGS312033E serves as a direct replacement for the legacy Series C ND312033 molded case circuit breaker. It upgrades the older design to the modern Digitrip 310 or 310+ RMS electronic platform.
No, this breaker is an 80 percent rated device. In accordance with standard electrical codes, the continuous load applied to the breaker should not exceed 960 amps, which is 80 percent of its 1200A nominal rating.
No, this unit comes standard with imperial tapped pads on the line and load sides. Mechanical or compression terminal lugs must be specified and purchased separately based on your conductor type and size requirements.
The NGS312033E accepts standard Eaton Series G internal accessories. Panel builders can add shunt trips, auxiliary switches, alarm switches, and undervoltage releases to meet specific control panel requirements.
The electronic Digitrip 310+ LS trip unit allows for precise adjustments of Long-Time (overload) and Short-Time (short circuit) parameters. This adjustability helps electricians safely coordinate the breaker's response time with other downstream electrical devices.
No, this specific model features an LS trip unit, meaning it provides Long-Time and Short-Time protection only. If ground fault protection is required for your installation, you must source a breaker variant equipped with an LSG trip unit.
Yes, the NGS312033E is reverse feed capable. This means electrical power can be safely supplied to either the line or load side terminals without affecting the breaker's performance, safety ratings, or tripping accuracy.
This unit mount breaker is engineered for integration into Eaton Series G panelboards, switchboards, and motor control centers. It is typically secured using a standard bolt-on connection method.
When equipped with the appropriate Eaton terminal lug kits, the connections on this breaker can accommodate copper or aluminum conductors ranging from 4 AWG up to 500 kcmil.
Yes, the NGS312033E carries an HACR rating. This certification ensures the breaker is rigorously tested and approved for safe use with heavy-duty heating, air conditioning, and refrigeration equipment in industrial facilities.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.