Eaton / Cutler-Hammer PDG22G0070TFFJ - 70A 2 Pole Molded Case Circuit Breaker

Eaton / Cutler-Hammer PDG22G0070TFFJ - 70A 2 Pole Molded Case Circuit Breaker

New

$696.00 In Stock

Quantity

Similar Items

Description

Operating at 70 amps, this globally rated Eaton MCCB delivers essential long-time and instantaneous (LI) protection. The Power Defense Frame 2 breaker is engineered to support heavy-duty commercial, marine, and industrial power systems. It installs easily into Eaton panelboards, switchboards, and Series C F-Frame enclosures. Facility managers can use this to replace discontinued HFD2070 and EGS2070FFG components. The unit boasts a 35kAIC rating at 480V and includes standard line and load lugs.

Specifications

Key specifications
Brand Eaton / Cutler-Hammer
Part Number PDG22G0070TFFJ
Series PDG2
Amperage 70A
Poles 2
Mounting Style Panel Mount
Voltage 240VAC, 480VAC, 600VAC, 250VDC
Phase 1
AIC Rating 65kA @ 240VAC, 35kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC
Fit and installation
Frame Type PDG
Terminal Type Lugs
For Use With Eaton Power Defense Panelboards, Switchboards, Enclosures, Series C F-Frame Panelboards
Wire Gauge 14-1/0 AWG (Al/Cu)
Max Wire 1/0 AWG
Min Wire 14 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Fixed Magnetic
Standards and features
Available Options Auxiliary Switch, Bell Alarm, Shunt Trip, Undervoltage Release, Padlock Attachment, Handle Mechanism
Accessories Line and Load Lugs Included (PDG2X2T100)
Standards CSA C22.2 No. 5, IEC 60947-2, UL 489, RoHS
Approval CCC, CE, CSA, IEC, RoHS, UL
Temp Rating -20C to 70C
Construction Features HACR Rated, RoHS Compliant

Product FAQs

8 answers
What panelboards and enclosures are compatible with the PDG22G0070TFFJ?

This breaker is designed for use in Eaton Power Defense panelboards, switchboards, and enclosures. It is also backward compatible with legacy Series C F-Frame panelboards.

Can the PDG22G0070TFFJ be used in DC applications?

Yes, this thermal-magnetic breaker is rated for up to 250VDC with a 10kA interrupting capacity, making it suitable for specific direct current control and distribution circuits.

What wire sizes are accepted by the standard lugs on this 70A breaker?

The factory-installed lugs accept 14 AWG to 1/0 AWG aluminum or copper (Al/Cu) conductors. Ensure proper torque specifications are applied during installation.

Can I use this Power Defense Frame 2 breaker to replace an older Cutler-Hammer Series C F-Frame breaker?

Yes, the Power Defense Frame 2 (PDG2) series shares the same physical footprint as the legacy Series C F-Frame, allowing it to serve as a direct replacement in existing installations.

Are the thermal and magnetic trip settings adjustable on this breaker?

No, the PDG22G0070TFFJ features a fixed thermal and fixed magnetic (LI) trip unit. If you require adjustable trip settings, an electronic trip unit or a different thermal-magnetic configuration is necessary.

How does the PDG22G0070TFFJ mount into a panel?

This is a feed-thru, panel-mount circuit breaker. It bolts directly to the chassis or mounting pan rather than plugging onto a busbar.

Does this breaker provide ground fault or arc fault protection?

No, the PDG22G0070TFFJ is a standard thermal-magnetic breaker providing long-time and instantaneous (LI) overcurrent and short-circuit protection. It does not include integrated ground fault (GFCI) or arc fault (AFCI) functions.

What does the "TFFJ" suffix in the catalog number signify?

In the Eaton Power Defense nomenclature, "TFF" indicates a thermal-magnetic trip unit with fixed thermal and fixed magnetic settings. The "J" designates standard feed-thru line and load terminals.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.