Eaton / Cutler-HammerPDG23M0080TFFJ
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | PDG2 |
| Amperage | 80A |
| Poles | 3 |
| Mounting Style | Panel Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480VAC, 35kA @ 600VAC, 22kA @ 250VDC |
| Frame Type | Complete Breaker |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Power Defense Enclosures and Panelboards |
| Wire Gauge | 14 AWG - 1/0 AWG (Al/Cu) |
| Max Wire | 1/0 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Bell Alarm, Shunt Trip, Undervoltage Release, Handle Mechanism, Handle Lock |
|---|---|
| Accessories | Load Side Terminals (PDG2X3T100) |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CCC, CE, CSA, IEC, RoHS, UL |
| Temp Rating | -25C to 70C |
| Construction Features | Current Limiting, RoHS Compliant |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | PDG2 |
| Amperage | 80A |
| Poles | 3 |
| Mounting Style | Panel Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480VAC, 35kA @ 600VAC, 22kA @ 250VDC |
| Frame Type | Complete Breaker |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Power Defense Enclosures and Panelboards |
| Wire Gauge | 14 AWG - 1/0 AWG (Al/Cu) |
| Max Wire | 1/0 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Bell Alarm, Shunt Trip, Undervoltage Release, Handle Mechanism, Handle Lock |
|---|---|
| Accessories | Load Side Terminals (PDG2X3T100) |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CCC, CE, CSA, IEC, RoHS, UL |
| Temp Rating | -25C to 70C |
| Construction Features | Current Limiting, RoHS Compliant |
Eaton / Cutler-HammerPDG23M0080TFFJ
Eaton / Cutler-HammerPDG23M0090TFFJ
Eaton / Cutler-HammerPDG23M0090TFFL
Eaton/Cutler-HammerPDG23M0070TFFL
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | PDG2 |
| Amperage | 80A |
| Poles | 3 |
| Mounting Style | Panel Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480VAC, 35kA @ 600VAC, 22kA @ 250VDC |
| Frame Type | Complete Breaker |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Power Defense Enclosures and Panelboards |
| Wire Gauge | 14 AWG - 1/0 AWG (Al/Cu) |
| Max Wire | 1/0 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Bell Alarm, Shunt Trip, Undervoltage Release, Handle Mechanism, Handle Lock |
|---|---|
| Accessories | Load Side Terminals (PDG2X3T100) |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CCC, CE, CSA, IEC, RoHS, UL |
| Temp Rating | -25C to 70C |
| Construction Features | Current Limiting, RoHS Compliant |
The 'M' in the catalog number designates the interrupting rating of the breaker, which is 65kAIC at 480VAC.
The 'TFFL' suffix indicates that the breaker is equipped with a Thermal Magnetic trip unit (T) featuring Fixed Thermal and Fixed Magnetic settings (FF), and it comes with factory-installed lugs on both the line and load sides (L).
No, this specific model features a fixed thermal and fixed magnetic trip unit. The long-time and instantaneous trip functions are factory set for 80 amps and cannot be adjusted.
This Frame 2 breaker features a bolt-on connection for secure panel mounting within Eaton Power Defense enclosures and panelboards. The included lugs accept 14 AWG to 1/0 AWG aluminum or copper (Al/Cu) conductors.
Always de-energize the panelboard before installing or servicing the breaker. Verify that all power sources are completely disconnected using a properly rated voltage tester, and ensure the installation complies with the National Electrical Code (NEC) and local regulations.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.