| Brand | ABB / General Electric |
|---|---|
| Part Number | FBV36TE030RV |
| Series | FBV |
| Amperage | 30A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600Y/347VAC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 35kA @ 480VAC, 22kA @ 600Y/347VAC |
| Frame Type | FB 100 |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series AD Panelboards |
| Wire Gauge | 10-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Bell Alarm, Shunt Trip, Undervoltage Release |
|---|---|
| Accessories | Load Side Lugs Included, Line Side Panel Connectors |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, HACR, UL |
| Temp Rating | -25C to 70C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed, Naval Rated |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | FBV36TE030RV |
| Series | FBV |
| Amperage | 30A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600Y/347VAC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 35kA @ 480VAC, 22kA @ 600Y/347VAC |
| Frame Type | FB 100 |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series AD Panelboards |
| Wire Gauge | 10-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Bell Alarm, Shunt Trip, Undervoltage Release |
|---|---|
| Accessories | Load Side Lugs Included, Line Side Panel Connectors |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, HACR, UL |
| Temp Rating | -25C to 70C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed, Naval Rated |
ABB / General ElectricFBV36TE035RV
ABB / General ElectricFBV36TE025RV
ABB / General ElectricFBV36TE040RV
ABB / General ElectricFBV36TE020RV
| Brand | ABB / General Electric |
|---|---|
| Part Number | FBV36TE030RV |
| Series | FBV |
| Amperage | 30A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600Y/347VAC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 35kA @ 480VAC, 22kA @ 600Y/347VAC |
| Frame Type | FB 100 |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series AD Panelboards |
| Wire Gauge | 10-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Bell Alarm, Shunt Trip, Undervoltage Release |
|---|---|
| Accessories | Load Side Lugs Included, Line Side Panel Connectors |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, HACR, UL |
| Temp Rating | -25C to 70C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed, Naval Rated |
This bolt-on MCCB is designed specifically for use in GE A-Series AD panelboards. It requires bolted connections directly to the panel bus and will not fit in standard plug-on load centers.
The factory-installed lugs accept wire gauges from 10 AWG to 4 AWG. They are dual-rated for both copper (Cu) and aluminum (Al) conductors.
ABB acquired GE Industrial Solutions. As a result, newer production runs of the FBV36TE030RV and other Record Plus breakers may feature ABB branding. They are exact replacements and fully interchangeable with older GE-branded units.
No. This breaker features fixed thermal and fixed magnetic trip functions (LI code). The long-time and instantaneous trip settings are factory-calibrated for 30 amps and cannot be modified by the user.
Yes. The GE Record Plus FB 100-amp frame utilizes a double-break rotary contact structure that makes it highly current-limiting. This design significantly reduces peak let-through current and arc flash energy during a fault.
Yes, GE Record Plus FB-frame circuit breakers carry an HACR rating. This makes them suitable for use with multi-motor and combination loads, such as heating, air conditioning, and refrigeration equipment.
Yes. Because these Record Plus FB-frame breakers do not have specific line and load markings, they are suitable for reverse feeding in applications that require it.
This breaker is built on the GE Record Plus FB 100-amp frame. While its internal thermal-magnetic trip unit is specifically calibrated for 30A, the physical exterior dimensions are identical to all other FB-frame breakers up to 100A.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.