The General Electric FCN36TE090R molded case circuit breaker is built to protect circuits against overloads and short circuits. Rated 90A and 600VAC, this 3-pole, 3-phase breaker has a 65kAIC interrupting rating at 480V. It uses an FCN frame in the Record Plus series and a bolt-on terminal connection. It provides standard protection with thermal magnetic tripping and LI - long-time and instantaneous trip functions.
GE Switchboards, Motor Control Centers, Enclosures, GE Spectra Panelboards (with retrofit kit)
Wire Gauge
4-1/0 AWG
Max Wire
1/0 AWG
Min Wire
4 AWG
Protection and operation
Trip Technology
Thermal Magnetic
Trip Function Code
LI
Trip Function
Long-Time, Instantaneous
Trip Adjustability
Fixed Thermal, Fixed Magnetic
Standards and features
Available Options
Auxiliary Switch, Bell Alarm, Lug Kits, Shunt Trip, Undervoltage Release
Standards
UL 489
Approval
CE, CSA, UL
Temp Rating
40C
Construction Features
HACR Rated, Current Limiting, Reverse Feed
Product FAQs
6 answers
What does the three-pole configuration mean for a three-phase circuit?
The three-pole configuration provides a breaker pole for each phase conductor in a three-phase circuit. Choose it when the circuit requires three-pole overcurrent protection.
How does the 600VAC rating guide voltage selection?
The circuit's AC voltage must be within the breaker's 600VAC rating. Evaluate interrupting capacity separately, since voltage rating and fault-current interruption are different selection requirements.
How do I check the 65kAIC interrupting rating at 480V?
For a 480V application, compare the available fault current at the installation point with the 65kAIC interrupting rating. The available fault current must not exceed that rating.
How does the thermal-magnetic LI trip protect the circuit?
The thermal-magnetic trip combines long-time protection for sustained overloads with instantaneous protection for high fault currents. This combination addresses both overload heating and faults requiring rapid interruption.
What should I plan for with bolt-on terminal connections?
Plan for bolted electrical joints at the terminals. Secure these connections using the appropriate tightening procedure to maintain reliable electrical contact.
How should I use the 90A rating when selecting the General Electric FCN36TE090R?
Compare the 90A rated current with the circuit's calculated load and conductor ampacity. These comparisons guide current-rating selection for load service and conductor overcurrent protection.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.