| Brand | ABB / General Electric |
|---|---|
| Part Number | TED136020 |
| Series | TED |
| Amperage | 20A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Lugs (TCAL14) |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CE, CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, HID Rated |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED136020 |
| Series | TED |
| Amperage | 20A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Lugs (TCAL14) |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CE, CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, HID Rated |
ABB / General ElectricTED134020
ABB / General ElectricTED134025
ABB / General ElectricTED134015
ABB / General ElectricTED136015
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED136020 |
| Series | TED |
| Amperage | 20A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Lugs (TCAL14) |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CE, CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, HID Rated |
This E-frame breaker is designed for bolt-on installation in GE A-Series panelboards, GE Spectra panelboards, switchboards, and motor control centers.
ABB acquired GE Industrial Solutions in 2018. As a result, TED series breakers may feature either ABB or GE branding depending on the production date. Both versions are identical in form, fit, and function.
The standard lugs accommodate 14 to 3 AWG copper (Cu) wire or 12 to 1 AWG aluminum (Al) wire.
Yes, GE TED series breakers are suitable for reverse feed applications. They do not have strict line and load directional restrictions.
To safely achieve the 500VDC rating, the breaker must be wired with its poles in series. It provides a 10kA interrupting capacity at this DC voltage for ungrounded battery applications.
The WL suffix indicates that the breaker is factory-equipped with standard copper and aluminum (Cu/Al) line and load lugs. The base TED136020 catalog number typically includes these same lugs.
Yes, this breaker is HACR rated, meaning it is approved for use with heating, air conditioning, and refrigeration equipment.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.