ABB / General ElectricTHED136060
Quantity
New
Quantity
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Series | THED |
| Amperage | 50A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Series Panelboards |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 1 AWG (Al), 3 AWG (Cu) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Padlock Attachment, Alarm Switch |
|---|---|
| Accessories | Load Lugs |
| Standards | UL 489, CSA C22.2 No. 5, NEMA AB-1 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, High Interrupting Capacity, Reverse Feed, Non-Interchangeable Trip, Quick-Make/Quick-Break, Trip-Free Mechanism, Common Trip |
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Series | THED |
| Amperage | 50A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Series Panelboards |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 1 AWG (Al), 3 AWG (Cu) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Padlock Attachment, Alarm Switch |
|---|---|
| Accessories | Load Lugs |
| Standards | UL 489, CSA C22.2 No. 5, NEMA AB-1 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, High Interrupting Capacity, Reverse Feed, Non-Interchangeable Trip, Quick-Make/Quick-Break, Trip-Free Mechanism, Common Trip |
ABB / General ElectricTHED136060
ABB / General ElectricTHED136040
ABB / General ElectricTHED136035
ABB / General ElectricTHED136070
| Brand | ABB / General Electric |
|---|---|
| Series | THED |
| Amperage | 50A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Series Panelboards |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 1 AWG (Al), 3 AWG (Cu) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Padlock Attachment, Alarm Switch |
|---|---|
| Accessories | Load Lugs |
| Standards | UL 489, CSA C22.2 No. 5, NEMA AB-1 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, High Interrupting Capacity, Reverse Feed, Non-Interchangeable Trip, Quick-Make/Quick-Break, Trip-Free Mechanism, Common Trip |
This breaker is designed for use in General Electric A-Series and Spectra Series panelboards. It uses a bolt-on connection and is not compatible with load centers that require standard plug-on breakers.
Both belong to the GE E150 line and share the same physical dimensions, but the H in THED designates a high-interrupting capacity. The THED136050 provides up to 25kAIC at 480VAC, whereas a standard TED breaker has a lower fault current rating, typically 18kAIC at 480VAC.
Yes, GE THED series molded case circuit breakers are suitable for reverse-feed applications. Always verify local electrical codes and ensure the breaker is properly labeled when back-feeding.
No. Even if the frame dimensions or amperage match, breakers are not interchangeable across manufacturers. You must use a GE or ABB E150 line breaker to maintain proper fitment and UL compliance in your GE panelboard.
ABB acquired GE Industrial Solutions. You may receive this breaker with either GE or ABB branding, but it is the exact same E150 line unit and is fully interchangeable in your existing panelboards.
No. If a THED breaker is specified, it means the available fault current at that location requires the higher interrupting rating. Installing a standard TED breaker could result in catastrophic failure during a short circuit.
Yes, this breaker carries a DC rating. It is capable of safely interrupting up to 10kA at 250VDC and 10kA at 500VDC, making it suitable for certain battery or solar distribution setups.
You cannot adjust the trip settings on this model. It features a thermal-magnetic trip unit with fixed long-time and fixed instantaneous (LI) trip functions.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.