ABB / General ElectricTHFK236150
Quantity
Re-Certified
Quantity
ABB / General ElectricTHFK236150
ABB / General ElectricTHFK236125
ABB / General ElectricTHFK236070
ABB / General ElectricTHFK236175WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | THFK236175-R |
| Series | THFK |
| Amperage | 175A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | 4 AWG - 300 kcmil (Cu/Al) |
| Max Wire | 300 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits, Padlock Attachment |
|---|---|
| Accessories | Load Lugs (TCAL24) |
| Standards | CSA C22.2 No. 5, HACR Rated, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, High Interrupting Capacity, Interchangeable Trip, Common Trip, Trip-Free Mechanism, Quick-Make/Quick-Break |
This legacy F-Frame breaker is designed for installation in GE A-Series panelboards, switchboards, and motor control centers.
No. According to GE specifications, TFK and THFK series circuit breakers are not suitable for reverse feed applications. If reverse feed is required, a TFJ series breaker is typically used.
Yes, the THFK series utilizes an interchangeable thermal-magnetic trip unit. This allows the trip unit to be replaced or upgraded within the 225A frame without replacing the entire breaker.
"THFK" designates a high-interrupting F-Frame breaker with an interchangeable trip. The "2" indicates a 225A maximum frame size, "3" is for 3 poles, "6" denotes a 600V maximum voltage rating, and "175" specifies the 175A trip rating.
Yes, this breaker is equipped with a fixed thermal and adjustable magnetic trip unit, allowing electricians to adjust the instantaneous trip settings to coordinate with other protective devices in the system.
The primary difference is the short-circuit interrupting capacity. TFK breakers have a standard interrupting rating of 22kAIC at 480V, while THFK breakers feature a high interrupting rating of 25kAIC at 480V. Both share the same physical F-Frame dimensions and utilize interchangeable trip units.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.