ABB / General ElectricTHFK236200WL
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THFK236225WL |
| Series | THFK |
| Amperage | 225A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, Switchboards, Motor Control Centers, Enclosures |
| Wire Gauge | 4 AWG - 300 kcmil (Cu/Al) |
| Max Wire | 300 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Line and Load Lugs Included (TCAL24) |
| Standards | CSA C22.2 No. 5, HACR Rated, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Interchangeable Trip Unit, High Interrupting Capacity, Trip-Free Mechanism, Common Trip |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THFK236225WL-R |
| Series | THFK |
| Amperage | 225A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, Switchboards, Motor Control Centers, Enclosures |
| Wire Gauge | 4 AWG - 300 kcmil (Cu/Al) |
| Max Wire | 300 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Line and Load Lugs Included (TCAL24) |
| Standards | CSA C22.2 No. 5, HACR Rated, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Interchangeable Trip Unit, High Interrupting Capacity, Trip-Free Mechanism, Common Trip |
ABB / General ElectricTHFK236200WL
ABB / General ElectricTHFK236175WL
ABB / General ElectricTHFK236150WL
ABB / General ElectricTHFK236125WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | THFK236225WL-R |
| Series | THFK |
| Amperage | 225A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, Switchboards, Motor Control Centers, Enclosures |
| Wire Gauge | 4 AWG - 300 kcmil (Cu/Al) |
| Max Wire | 300 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Line and Load Lugs Included (TCAL24) |
| Standards | CSA C22.2 No. 5, HACR Rated, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Interchangeable Trip Unit, High Interrupting Capacity, Trip-Free Mechanism, Common Trip |
The WL suffix signifies that the breaker includes factory-installed line and load lugs. Models without this suffix are typically supplied unassembled without terminal lugs. For this 225-amp F225 frame, it utilizes TCAL24 lugs.
Yes, the legacy F225 frame has been replaced by the ABB Tmax XT3 and XT4 molded case circuit breakers, as well as the GE Spectra RMS line. Upgrading to a newer frame may require an adapter kit or different mounting hardware depending on your panelboard.
It is designed to integrate into legacy GE A-Series panelboards, motor control centers, switchboards, and standalone NEMA enclosures that accept F225 frame dimensions.
Yes, the THFK and TFK breakers feature interchangeable thermal-magnetic trip units. This allows electricians to swap the trip mechanism to adjust the maximum continuous current protection without replacing the entire breaker frame.
It features a fixed thermal element for standard overload protection combined with an adjustable magnetic trip. The magnetic setting allows you to adjust the instantaneous short-circuit pickup threshold, which is critical for avoiding nuisance tripping on inductive loads like large motors.
The standard TCAL24 lugs are dual-rated for copper (Cu) and aluminum (Al) wire, accommodating conductor sizes from 4 AWG up to 300 kcmil. Ensure proper torque specifications are met during installation based on the conductor material.
The LI designation means the breaker provides Long-Time (L) overcurrent protection and Instantaneous (I) short-circuit protection. It does not include Short-Time (S) or Ground Fault (G) functions found on solid-state LSIG breakers.
Yes, it is rated for up to 250VDC applications with a 10 kAIC interrupting capacity. It provides reliable protection for industrial DC power distribution systems.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.