| Brand | ABB / General Electric |
|---|---|
| Part Number | THQC2140 |
| Series | THQC |
| Amperage | 40A |
| Poles | 2 |
| Mounting Style | DIN Rail |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE Q-Line Enclosures, DIN Rail, OEM Panels |
| Wire Gauge | 8-3 AWG (Cu), 8-3 AWG (Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Padlock Attachment |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 10C to 50C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break, Non-Interchangeable Trip |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQC2140-R |
| Series | THQC |
| Amperage | 40A |
| Poles | 2 |
| Mounting Style | DIN Rail |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE Q-Line Enclosures, DIN Rail, OEM Panels |
| Wire Gauge | 8-3 AWG (Cu), 8-3 AWG (Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Padlock Attachment |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 10C to 50C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break, Non-Interchangeable Trip |
ABB / General ElectricTHQC2140WL
ABB / General ElectricTHQC2145WL
ABB / General ElectricTHQC2135
ABB / General ElectricTHQC2135WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQC2140 |
| Series | THQC |
| Amperage | 40A |
| Poles | 2 |
| Mounting Style | DIN Rail |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE Q-Line Enclosures, DIN Rail, OEM Panels |
| Wire Gauge | 8-3 AWG (Cu), 8-3 AWG (Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Padlock Attachment |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 10C to 50C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break, Non-Interchangeable Trip |
This breaker is designed for installation in GE Q-Line enclosures and various OEM panels. It is also compatible with standard DIN rail systems for flexible mounting in industrial control panels.
The factory-installed lugs on this breaker accept 8 AWG to 3 AWG wire. The terminals are dual-rated for use with both copper and aluminum conductors.
It utilizes a bolt-on connection for a secure, vibration-resistant fit in compatible panels, and it can also be mounted directly onto a standard 35mm DIN rail.
The fixed thermal magnetic unit provides Long-Time protection for sustained overloads and Instantaneous protection to quickly clear severe short circuits.
No, this breaker features a fixed thermal magnetic trip unit. The trip settings cannot be adjusted in the field.
Yes. As a 2-pole Q-Line breaker, it features an internal common trip bar that ensures both poles open simultaneously during a fault, preventing single-phasing on connected loads.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.