Schneider Electric M9R12463 4 Pole Circuit Breaker
The Schneider Electric M9R12463 is a 4 Pole thermal magnetic molded case circuit breaker with a current rating of 63 Amps and a voltage rating of 480Y/277VAC. It has an interrupting rating of 10kAIC at 240VAC. The M9R12463 has a DIN rail mounting type.
Specifications
Key specifications
Amperage
63A
Voltage
480Y/277VAC, 415VAC
Series
Multi9
Poles
4
Electrical ratings
Phase
3
Interrupting Rating
10kAIC at 240VAC
Fit and installation
Mounting Type
DIN Rail
Terminal Connection
Tunnel
Length (in)
2.4
Width (in)
2.8
Height (in)
3.2
Configuration
Single
Max Wire Size
AWG 2
Min Wire Size
AWG 18
Protection and operation
Protection
GFEP
Circuit Breaker Type
Low Voltage
Actuator Type
Toggle
Standards and features
Approval
UL, EN/IEC
Standards
RoHS, REACh
Temperature Rating
-25 to 60 °C
Product details
Brand
Schneider Electric
Color
Gray
Product FAQs
8 answers
What is the ground fault sensitivity rating for the M9R12463 RCCB?
This Multi9 GFP residual current circuit breaker has an earth leakage sensitivity of 86mA under UL 1053 standards and 100mA under IEC 61008-1 standards.
What type of residual current protection does the M9R12463 provide?
It features Type A-SI (Super Immunized) protection. This class is designed to handle AC and pulsating DC residual currents while resisting nuisance tripping from transient surges in industrial environments.
What wire sizes are compatible with the tunnel terminals on the M9R12463?
The terminals accept 18 AWG to 2 AWG rigid copper wire, or 18 AWG to 3 AWG flexible copper wire.
What is the recommended tightening torque for the terminal connections?
The top and bottom tunnel terminals should be torqued to 30.98 lb-in (3.5 N.m).
How much insulation should be stripped from the wire before terminating?
The recommended wire stripping length for the top and bottom connections is 0.55 inches (14 mm).
How much DIN rail space does this 4-pole RCCB require?
The M9R12463 occupies 4 standard 18mm modules, requiring a total width of 72mm (2.83 inches) on a 35mm DIN rail.
Can auxiliary contacts or shunt trips be added to the M9R12463?
Yes, it is compatible with select Multi9 electrical auxiliaries, including the 26923 auxiliary contact and M9A26478 shunt trip release.
Does the M9R12463 provide overcurrent and short-circuit protection?
No, this is a Residual Current Circuit Breaker (RCCB) designed strictly for ground fault protection. It must be paired with an appropriate upstream circuit breaker or fuse for overload and short-circuit protection.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.