Schneider Electric M9R84440 4 Pole Circuit Breaker
The Schneider Electric M9R84440 is a 4 Pole thermal magnetic molded case circuit breaker with a current rating of 40 Amps and a voltage rating of 480Y/277VAC. It has an interrupting rating of 1.5kAIC at 240VAC. The M9R84440 has a DIN rail mounting type.
Specifications
Key specifications
Amperage
40A
Voltage
240VAC, 480Y/277VAC
Series
Multi9
Poles
4
Electrical ratings
Phase
3
Interrupting Rating
1.5kAIC at 240VAC
Fit and installation
Mounting Type
DIN Rail
Terminal Connection
Tunnel
Length (in)
2.4
Width (in)
2.8
Height (in)
3.2
Configuration
Single
Max Wire Size
AWG 2
Min Wire Size
AWG 18
Protection and operation
Protection
GFEP
Circuit Breaker Type
Low Voltage
Actuator Type
Toggle
Standards and features
Approval
UL, EN/IEC, CCC
Standards
RoHS, REACh
Temperature Rating
-25 to 60 °C
Product details
Brand
Schneider Electric
Color
Gray
Product FAQs
8 answers
What is the earth-leakage sensitivity rating for the M9R84440?
This Multi9 Ground Fault Protector (GFP) has an earth-leakage sensitivity of 260 mA according to UL 1053 standards and 300 mA under EN/IEC 61008-1 standards.
What does the Type A-SI classification indicate on this residual current circuit breaker?
The Type A-SI (Super Immunized) classification means the breaker offers enhanced immunity to electrical network disturbances, which helps prevent nuisance tripping in environments with high electrical noise.
How much DIN rail space is required to mount this 4-pole breaker?
The breaker has a total width of 72 mm, which occupies eight standard 9 mm pitches on a 35mm DIN rail.
What wire sizes are accepted by the terminals on the M9R84440?
The top and bottom tunnel terminals accept rigid copper wiring from AWG 18 to AWG 2 and flexible wiring from AWG 18 to AWG 3.
Is this breaker compatible with both 50 Hz and 60 Hz electrical networks?
Yes, it is rated for use on both 50 Hz and 60 Hz networks, supporting 480Y/277VAC at 60 Hz and up to 415VAC at 50 Hz.
Does this breaker feature a local status indicator for fault tripping?
Yes, the front panel includes a mechanical status indicator that displays a red signal to indicate when the device has tripped due to a fault.
What are the compatible auxiliary contacts for the M9R84440?
This breaker is compatible with Multi9 auxiliary contacts, such as the Schneider Electric 26923 designed specifically for RCCB top connection.
What is the operating temperature range for this Multi9 GFP breaker?
The M9R84440 is rated for operation in ambient air temperatures ranging from -25 degrees Celsius to 60 degrees Celsius.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.